![Sony HANDYCAM HVR-S270P Скачать руководство пользователя страница 282](http://html.mh-extra.com/html/sony/handycam-hvr-s270p/handycam-hvr-s270p_service-manual_404915282.webp)
6-48
HVR-S270J/S270U/S270N/S270E/S270P/S270C
17. Auto White Balance Standard Data Input
(ND2)
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (Color reproduction
adjustment frame)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
8C to 8F
Specified Value
Data of page: 6 address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input (ND1
(CLR))” before this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
99
Check the data is “01”.
3
6
02
Check the data is “00”.
4
6
07
Check the data is “04”.
5
0
10
01
6
6
07
Check the data is “04”.
(16)
7
0
10
00
8
6
61
01
9
Wait for 3 seconds.
10
0
10
01
11
6
40
01
(16)
12
0
10
00
13
6
41
01
14
6
01
0B
Press PAUSE (Write) button.
(Note 4)
15
6
02
Check the data changes to
“01”.
16
6
0C
Check the data is “00”.
Note 4:
The adjustment data will be automatically input to page:
6F, address: 8C to 8F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
10
01
3
6
40
00
(16)
4
0
10
00
5
6
41
00
6
6
61
00
7
Wait for 3 seconds.
8
0
01
00