![Sony HANDYCAM HVR-S270P Скачать руководство пользователя страница 274](http://html.mh-extra.com/html/sony/handycam-hvr-s270p/handycam-hvr-s270p_service-manual_404915274.webp)
6-40
HVR-S270J/S270U/S270N/S270E/S270P/S270C
9.
Picture Frame Setting
(Color reproduction adjustment frame)
Subject
Color bar chart
(Color reproduction adjustment
frame)
40 cm (PTB-1450) from the front of
lens)
Measurement Point
VIDEO OUT jack
(75
Ω
terminated)
Measuring Instrument
Oscilloscope and monitor TV (16:9)
Specified Value
A=B, C=D, E=F
Note 1:
“Flange Back Adjustment” before this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
2) FOCUS ring (Lens block) .......................................... Mode A
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Setting method:
Order Page Address Data
Procedure
1
0
10
01
2
6
40
01
(16)
3
Adjust the zoom and the
camera direction, and set the
specified position.
4
Mark the position of the
picture frame on the monitor
TV, and adjust the picture
frame to this position in
following adjustment using
“Color reproduction
adjustment frame”.
5
0
10
00
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
0
10
01
2
6
40
01
(16)
3
6
2C
01
(16)
4
6
90
XL
(16)
5
6
91
XH
(16)
6
6
92
YL
(16)
7
6
93
YH
(16)
8
6
01
79
Press PAUSE (Write) button.
(16)
9
0
10
00
How to release the picture frame setting:
Order Page Address Data
Procedure
1
0
10
01
2
6
40
01
(16)
3
6
01
00
Press PAUSE (Write) button.
(16)
4
6
90
00
(16)
5
6
91
00
(16)
6
6
92
00
(16)
7
6
93
00
(16)
8
6
2C
00
(16)
9
0
10
00