![Sony HANDYCAM HVR-S270P Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/sony/handycam-hvr-s270p/handycam-hvr-s270p_service-manual_404915266.webp)
6-32
HVR-S270J/S270U/S270N/S270E/S270P/S270C
5-3. Optical Path Differencial Adjustment (ND3)
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the minipattern box or flange back adjust-
ment jig)
Perform the flange back adjustment on the body side, if the ND
filter is set to ND3. In whichever case, the focus will be deviated
during auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
minipattern box (Note 1) or flange
back adjustment jig
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
24, 25, 2A
Specified value
Data of pege: 16, address: 0C is “00”
Note 1:
Dark Siemens star chart.
Note 2:
Perform the adjustment with the lens in horizontal state.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
Don't touch the zoom lever during adjustment.
Note 6:
After adjustment, if the focusing to a subject located at
infinity failed, increase the ilIlluminance of the chart and
perform readjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
09
3
F
26
Set the bit value of bit0 is “1”,
(9F)
and press PAUSE (Write)
button. (Note 7)
4
0
10
00
5
6
07
Check the data is “04”.
6
0
10
01
7
6
07
Check the data is “04”.
(16)
8
0
10
00
9
6
61
01
10
Wait for 3 seconds.
11
6
99
Check the data is “02”.
12
0
10
01
13
6
02
Check the data is “00”.
(16)
14
0
10
00
15
6
02
Check the data is “00”.
16
0
10
01
17
6
2C
01
(16)
18
0
10
00
19
6
4D
40
20
6
64
04
21
6
01
13
Press PAUSE (Write) button.
22
0
10
01
23
6
01
13
Press PAUSE (Write) button.
(16)
24
Wait for 1 seconds.
25
0
10
00
26
6
01
51
Press PAUSE (Write) button.
(Note 8)
27
0
10
01
28
6
01
51
Press PAUSE (Write) button.
(16)
(Note 8)
29
0
10
00
30
6
02
Check the data changes to
“01”.
31
0
10
01
32
6
0C
Check the data is “00”.
(16)
Note 7:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 8:
The adjustment data will be automatically input to page:
6F, address: 24, 25, 2A.