![Sony HANDYCAM HVR-S270P Скачать руководство пользователя страница 342](http://html.mh-extra.com/html/sony/handycam-hvr-s270p/handycam-hvr-s270p_service-manual_404915342.webp)
6-108
HVR-S270J/S270U/S270N/S270E/S270P/S270C
Note 3:
If bit0 of the data is “1”, the EVEN channel is defective.
If bit1 of the data is “1”, the ODD channel is defective.
Contents of the defect is see written into page: C, ad-
dress: 10 and 12. See following table.
(For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.)
If bit3 of the data is “1”, the tape end being played, so
rewind the tape and perform the adjustment again.
When the EVEN channel is defective
Data of page: C,
Contents of defect
address: 10
EE
Writing into Flash memory (IC2402) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC2601
When the ODD channel is defective
Data of page: C,
Contents of defect
address: 12
EE
Writing into Flash memory (IC2402) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC2601
2.
Switching Position Adjustment (VC-513 board)
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
VTR playback (VCR mode)
Signal
SW/OL standard (XH2-3)
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified value
The data of page: 3, address: 03 is
“00”
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Insert the SW/OL standard
tape and enter the VTR stop
mode.
2
0
01
01
3
3
71
01
Press PAUSE (Write) button.
4
C
10
EE
Press PAUSE (Write) button.
5
3
03
FF
6
3
21
Check the data is “02”. (Note 2)
7
3
01
0D
Press PAUSE (Write) button.
8
3
02
Check the data changes to “00”.
9
3
03
Check the data is “00”. (Note 3)
10
3
01
00
Press PAUSE (Write) button.
11
3
70
10
Press PAUSE (Write) button.
12
3
70
Check the data changes to
“11”.
13
0
01
00
Note 2:
If the data is “72”, the tape top being played. After play-
ing the tape for 1 to 2 seconds, stop it, perform step 5 and
higher.
If the data is “62”, the tape end being played. After re-
wind the tape, perform step 5 and higher.