5-37
2-2.
DIGITAL8 MODE
2-2-1.
HOW TO ENTER RECORD MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, and set data: 0C, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note:
The function buttons becomes inoperable.
5)
To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the record mode, be
sure to quit following this procedure.)
2-2-2.
HOW TO ENTER PLAYBACK MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, and set data: 0B, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note:
The function buttons becomes inoperable.
5)
To quit the playback mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the playback mode,
be sure to quit following this procedure.)
2-2-3.
OVERALL TAPE PATH CHECK
1. Recording of the tape path check signal
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Set to the camera recording mode.
5)
Select page: 3, address: 1C, set data: 5D, and press the PAUSE
button of the adjustment remote commander.
6)
Record for several minutes.
7)
Release the recording mode.
8)
Select page: 3, address: 1C, set data: 00, and press the PAUSE
button.
2. Tape path check
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Connect an oscilloscope to VC-254 board CN1108 via the CPC-
13 jig (J-6082-443-A).
Channel 1: VC-254 board, CN1108 Pin
qh
(Note)
External trigger: VC-254 board, CN1108 Pin
qd
Note:
Connect a 75
Ω
resistor between Pins
qh
of CN1108 and
6
(GND).
5)
Select page: 2, address: 2E, and set data: 01.
6)
Playback the tape path check signal.
7)
Select page: 3, address: 33, and set data: 08.
8)
Select page: 3, address: 26, and set data: 31.
9)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, perform “2-1-2. TAPE PATH ADJUSTMENT “ of
“2-1. Hi8/STANDARD 8 MODE”.
10) Select page: 3, address: 26, and set data: 00.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: 2, address: 2E, and set data: 00.
Fig. 5-2-2.
Must be flat
Pin
qd
Pin
qh
Содержание Handycam DCR-TRV230E
Страница 111: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 57 DIGITAL STILL CONTROL DS STILL PROCESS PC 082 ...
Страница 117: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 69 4 70 USER FUNCTION EVF DRIVE CF 079 ...
Страница 119: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 73 4 74 USER FUNCTION EVF DRIVE CF 080 ...
Страница 142: ...5 1 DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E SECTION 5 ADJUSTMENTS ...
Страница 239: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 304 OPTICAL AXIS FRAME ...
Страница 242: ...Revision History Ver 1 0 Date 2001 02 History Official Release Contents S M Rev issued 992987911 pdf Reverse ...