5-34
2.
Emergence Memory Address
Page C
Address 38 to 43
Address
Contents
38
EMG code when first error occurs
3A
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
3B
Lower: MSW code to be moved when first error
occurs
3C
EMG code when second error occurs
3E
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
3F
Lower: MSW code to be moved when second error
occurs
40
EMG code when last error occurs
42
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
43
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (38 to 43). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (38 to 3B). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (3C to 3F).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (40 to 43).
Note 2:
After completing adjustments, be sure to initialize the
data of addresses 38 to 43 to “00”.
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: C, address: 38, set data: 00, and press the PAUSE
button.
3) Select address: 39 to 43 and set data “00” into them in the
same way as in address: 10.
4) Select page: 0, address: 01, and set data: 00.
5-2-3. SERVICE MODE
1.
Setting the Test Mode
Page E
Address 10
Data
Function
00
Normal
02
Forced power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page E, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off (12 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.