1-13-1. Reset of Breaker
Overcurrent in the internal circuitry will trip the circuit breaker. If the breaker trips once, turn off the
power and check the circuit for overcurrent. Before turning off the power, be sure to disconnect the cable
connected at the DC IN connector or the battery, in addition to turning off the power switch.
Press the breaker reset button shown in the figure and the power to the unit will be turned on.
1-13-2. Information on IC Link
The unit is equipped with two IC links. One is F1 on the FL-251 board, and the other is PS600 on the CP-
317 board. F1 on the FL-251 board will blow when the overcurrent flows because of internal circuit
failure. PS600 on the CP-317 board will blow by overcurrent when an equipment connected at the DC
OUT connector fails. If some IC link blows, turn off the power and check the circuit for overcurrent.
Before turning off the power, be sure to disconnect the cable connected at the DC IN connector or the
battery, in addition to turning off the power switch.
When replacing, be sure to use the specified part.
w
The IC links are critical for safe operation. Be sure to replace them with the specified parts to avoid the
danger of a fire or electric shock.
Board
Ref.No.
Description
Part No.
FL-251
F1
IC LINK 0.4 A
!
1-576-122-21
CP-317
PS600
IC LINK 2 A
!
1-533-282-21
1-13. Power Protection
Breaker reset button
Содержание DNW-A220
Страница 6: ......
Страница 52: ...1 44 DNW A220 DNW A220P 1 15 Fixtures and Adjustment Equipment List 1 2 3 4 5 6 7 8 9 d l s d l ...
Страница 60: ......
Страница 76: ......
Страница 152: ......
Страница 158: ......
Страница 163: ......
Страница 170: ......
Страница 190: ...Printed in Japan Sony Corporation 2001 9 08 B P Company 1997 DNW A220 SY DNW A220P SY E 3 194 203 15 ...