1-29
DNW-A220
DNW-A220P
Ref.No.
Switch name
Description
Factory setting
S1701-1
Y MUTE
OFF: Normal mode
OFF
ON: Luminance signal is muted
S1701-2
Factory use
OFF
S1701-3
Factory use
OFF
S1701-4
C MUTE
OFF: Normal mode
OFF
ON: Color difference signal is muted
S1701-5
COMB
Selects whether a comb filter is turned on or off when
OFF
the color difference signal has the significant line crawl which
the LCC cannot correct
OFF: Normal mode (Comb filter is turned off)
ON: Comb filter is turned on
S1701-6
Factory use
OFF
S1701-7
Factory use
OFF
S1701-8
Factory use
OFF
S1801-1
D CLP OFF
Turns on and off the digital clamp function
OFF
Usually turn off this switch, and a DC difference between
(Digital clamp ON)
B-Y and R-Y signals (if present) is corrected by the digital
clamp function
Turn on only to turn off the digital clamp for test
OFF: Normal mode (Digital clamp is turned on)
ON: Digital clamp is turned off
S1801-2
Factory use
OFF
S1803-3
Factory use
OFF
S1803-4
Factory use
OFF
1-9. Settings for Internal Switches/Slit Lands