1-33
DNW-A220
DNW-A220P
1-10. Description on Internal Indicators
SDI-23 Board
n
The indicators D302 to D305 function properly when the received signal conforms to the EDH
*
(with
D301 lit).
*
EDH : Error Detection and Handling
Ref.No. Indictor name
Color
Description
Normal state
D300
SDI INPUT EXIT
Green
Lit when detecting the SDI format signal input
Lit
at SDI IN connector
D301
RX EDH VALIDITY
Green
Lit when the received signal at SDI IN connector
Lit
conforms to the EDH
D302
RX EDH OTHER
Red
Lit when another ancillary data exists in the EDH portion
Dark
ANC ERROR
of the received signal at SDI IN connector
D303
RX EDH ACTIVE
Red
Lit when an active picture EDH error is detected from the
Dark
PICTURE ERROR
received signal at SDI IN connector
D304
RX EDH FULL
Red
Lit when a full-field EDH error is detected from the
Dark
FIELD ERROR
received signal at SDI IN connector
D305
RX EDH ANCILLARY
Red
Lit when an ancillary data EDH error is detected from
Dark
DATA ERROR
the received signal at SDI IN connector
D800
SDI TRS NO ERROR
Green
Lit when the SDI format signal is normally received
Lit
at SDI IN connector
D801
VCO ADJ OF
Green
Lit when EVR (electronic volume) data comes near its
–––
MAINTENANCE
proper value during VCO free-run adjustment in the
maintenance mode
1-10. Description on Internal Indicators
D201
D300
D301
D302
D303
D304
D305
D800
D801
D201
D202
D202
D203
D203
D204
D204
SY-260 board
SY-259/259A board
SDI-23 board
Содержание DNW-A220
Страница 6: ......
Страница 52: ...1 44 DNW A220 DNW A220P 1 15 Fixtures and Adjustment Equipment List 1 2 3 4 5 6 7 8 9 d l s d l ...
Страница 60: ......
Страница 76: ......
Страница 152: ......
Страница 158: ......
Страница 163: ......
Страница 170: ......
Страница 190: ...Printed in Japan Sony Corporation 2001 9 08 B P Company 1997 DNW A220 SY DNW A220P SY E 3 194 203 15 ...