Factory-set
TEST
Factory-set
TEST
DM-114 Board (B Side)
E102
E302
TP104
TP304
DM-114/114P Board
Switches
n
Do not change settings of the factory-use switches.
Ref.No.
Switch name
Description
Factory setting
S101
Y EQ TEST
Test signal connection switch for Y RF LPF&EQ adjustment
See illustration
In adjusting, input the test signal to TP104 (GND to E102) with
S101 set to TEST (see illustration) position
S301
C EQ TEST
Test signal connection switch for C RF LPF&EQ adjustment
See illustration
In adjusting, input the test signal to TP304 (GND to E302) with
S301 set to TEST (see illustration) position
S501
Factory use
OFF
S901-1
ADJ
Use for RF EQ adjustment.
OFF
OFF: Normal mode
ON: Adjustment/Test mode
S901-2
Factory use
OFF
S901-3
AGC OFF
Turns on and off the AGC function during RF EQ adjustment
OFF
OFF: Normal mode (AGC is turned on)
ON: AGC is turned off
S901-4
Factory use
OFF
1-9. Settings for Internal Switches/Slit Lands