7-26
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
B
A
CTL head
TG-2 (Entrance guide)
<CTL output waveform>
CH-1: TP321/SS-63 board (CTL SIG signal)
TRIG: TP325/SS-63 board (SS GOP signal)
<SS-63 board, side A>
A
B
C
D
E
F
G
H
TP325
J
K
L
M
N
P
R
1
2
TP321
Preparation
1. Turn the Power Off
2. Connect the Oscilloscope
CH-1 : TP321/SS-63 board (CTL signal)
TRIG : TP325/SS-63 board (SS GOP signal)
Oscilloscope setting :
CH-1 : 2 V/DIV
TIME : 5 ms/DIV
3. Set the Alignment Tape
Set the SR2-1/P and put a weight on the cassette
so that it does not rise up.
Weight about 1000 g is suitable.
Check
4. Turn the Power On
5. Play Back the Alignment Tape
Play back the SR2-1/P (15:00 to 27:00).
6. Check the CTL Head Height
(1) Check that the level decreases when portion
A of the tape shown in the figure is pressed
down.
If the level increases, perform step 7.
(2) Check that the level decreases when portion
B of the tape is pushed up.
If the level increases, perform step 8.
Preparation
7-1-4. CTL Head Height Check and Adjustment
.
Alignment tape : SR2-1/SR2-1P (15:00 to 27:00)
CTL Head Height Check
Spec.: The level decreases when pressing down and
pushing up the alignment tape.
.
Connection of the oscilloscope
7-1-4. CTL Head Height Check and Adjustment
Tools
.
Alignment tape SR2-1 (For 525/60 system):
8-960-075-11
.
Alignment tape SR2-1P (For 625/50 system): 8-960-075-61
.
Oscilloscope (Tektronix 2465B or equivalent)
.
Tape guide adjustment driver (MW-261):
J-6322-610-A