4-4
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
Setting of Unit Side
1.
Turn on the power.
2.
Set S1100-1 on the SS-63 board to ON (CLOSE) to treat the extended menu.
3.
Set the setup extended menu.
.
For BKDW-505
Set the ITEM-713 as follows.
ITEM
SUB-ITEM
Setting
Previous setting (fill up)
713: VIDEO SETUP REFERENCE LEVEL
0.MASTER LEVEL
0.0 %
1. INPUT LEVEL
MSTER
2. V BLK REMOVE CNT
REMOV
3. BETACAM PB LEVEL
MSTER
4. OUTPUT LEVEL
MSTER
.
For BKDW-506
None.
n
The sub mode and menu of the maintenance mode that is used in Section 4-1 is as shown below.
SS-63 board
ON
OFF
S1100
Set S1100-1 to ON
M0: TAPE MAINTENANCE
C2: AUDIO/VIDEO CHECK
C21: VIDEO TEST SG
C22: MULTI LOOP (10 TIMES)
A2: AUDIO/VIDEO ADJUST
A24: INPUT CF DETECT
A25: DEC VR
A26: DEC VR (LOOP)
A2F: NV-RAM CONTROL
4-1. DEC-65 Board (BKDW-505/506)