6-35
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
6-3. Analog Video Playback System Adjustment after Replacing the Drum
6-3-11. TBC Y/C Delay Adjustment
n
Perform this adjustment without extending the TBC-24 board.
Measuring equipment: Component waveform monitor
(1) Turn on the power.
(2) Set the component waveform monitor to BOWTIE mode.
METAL adjustment [up to step (4)]
(3) Playback the bowtie signal portion (17:00 to 19:00) of the alignment tape CR5-1B or CR5-1B PS.
(DNW-A100/A50/A45: CR5-1B, DNW-A100P/A50P/A45P: CR5-1B PS)
(4) Observe the bowtie dip point at which the CH-1 (Y) and CH-2 (B-Y) signals cross. Adjust so that the
deviation between the center marker and bowtie dip point is within specification. Then observe the
point at which the CH-1 (Y) and CH-3 (R-Y) signals cross and adjust in the same manner.
Adjustment points: Field 1:
1
RV500/TBC-24(B-1)
Field 2:
1
RV504/TBC-24(C-1)
Specifications:
A = 0
±
10 ns
B = 0
±
10 ns
n
RV504 exists on the TBC-24 board with the suffix -13 and higher.
For the TBC-24 board with the suffix -11 or -12, adjust RV500 only.
(5)
Eject the alignment tape CR5-1B/CR5-1B PS.
RV500 and RV504 on TBC-24 Board
RV201
RV200
RV500
RV501
RV300
RV101
RV201
RV500
RV501
RV300
RV101
RV504
TBC-24 board (suffix-11 and 12)
TBC-24 board (suffix-13 and higher)
CH-1/CH-2
CH-1/CH-3
Center markers
A
B