6-42
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
6-4-3. LAU Dolby Level Adjustment
Measuring equipment: Audio level meter
CH1 adjustment
1.
Connect the audio level meter to TP501/APR-12(C-1).
GND : E500/APR-12(B-1)
2.
Playback the 1 kHz, 0 VU portion (0:00 to 2:55) of alignment tape CR8-1A or CR8-1B PS, and
perform the level adjustment.
(DNW-A100/A50/A45: CR8-1A, DNW-A100P/A50P/A45P: CR8-1B PS)
Adjustment point:
1
RV503/APR-12(C-1)
Specification:
_
10.0
±
0.2 dBu (0 dBu
=
0.775 V rms)
CH2 adjustment
3.
Connect the audio level meter to TP601/APR-12(E-1).
GND : E600/APR-12(F-1)
4.
Playback the 1 kHz, 0 VU portion (0:00 to 2:55) of alignment tape CR8-1A or CR8-1B PS, and
perform the level adjustment.
(DNW-A100/A50/A45: CR8-1A, DNW-A100P/A50P/A45P: CR8-1B PS)
Adjustment point:
1
RV604/APR-12(E-1)
Specification:
_
10.0
±
0.2 dBu (0 dBu
=
0.775 V rms)
APR-12 Board (Side A)
S600
RV600
RV601
RV602
TP600
RV603
TP601
RV604
RV605
E600
TP501
RV503
TP500
RV501
RV502
RV500
S500
RV203
E200
TP700 TP560
RV202
COR201
20 18 16
RV200
TP201
TP200
RV201
RV103
E100
RV102
COR200
0
–3
–20
+4
COR101
20 18 16
TP101
RV100
TP100
RV101
COR100
0
–3
–20
+4
COR400
16 18 20
COR401
VAR (R)
UNITY (R)
TP400
RV400
E400
TP701
COR402
+4
0
–3
–20
COR300
16 18 20
COR301
VAR (L)
UNITY (L)
TP300
RV300
E300
COR302
+4
0
–3
–20
1
2
3
4
5
6
7
A
A
B
RV504
E500
C
D
E
F
G
A No.
LOTNO,
S NO,
APR–12
1-661-132-
MADE IN JAPAN
>EP–GW<
6-4. Electrical Adjustment after Replacing the AT Head