5-66
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
5-10. Capstan Motor Replacement
Replace the capstan motor every 6,000 hours of tape running.
Outline
Replacement
1.
Remove the Video Head Cleaner Assembly
2.
Remove the Demagnetization Head Assembly
3.
Remove the Capstan Motor
4.
Attach the Capstan Motor
5.
Attach the DR-315 Board
6.
Attach the HDD Unit
7.
Attach the Demagnetization Head Assembly
8.
Attach the Video Head Cleaner Assembly
9.
Cleaning (Capstan Motor Shaft)
Adjustment after Replacement
10. Confirm the Pinch Press Clearance (Refer to Section 5-12-2.)
11. Confirm the Tape Running (Refer to Section 7-1-2.)
12. Perform the Capstan Motor Operation Check
(Refer to Section 4-2-2 in Maintenance Manual Part 1.)
(C014: CAPSTAN MOTOR)
13. Perform the Capstan FG Duty Adjust
(Refer to Section 4-2-7 in Maintenance Manual Part 1.)
(A003: CAPSTAN FG DUTY)
14. Perform the Capstan Free Speed Adjust
(Refer to Section 4-2-7 in Maintenance Manual Part 1.)
(A010: CAPSTAN FREE SPEED)
15. Perform the Adjusted Data Save
(Refer to Section 4-2-7 in Maintenance Manual Part 1.)
(A023: NV-RAM CONTROL)
Preparation
1.
Turn the power off.
2.
Remove the upper lid. (Refer to Section 2-3-1 in Maintenance Manual Part 1.)
3.
Remove the plate MD assembly.
(Refer to Section 2-4-2 in Maintenance Manual Part 1.)
4.
Remove the cassette compartment.
(Refer to Section 2-5 in Maintenance Manual Part 1.)
5.
Remove the bottom plate with the right side panel of the unit down.
(Refer to Section 2-3-1 in Maintenance Manual Part 1.)
6.
Remove the plate HDD unit. (Refer to 5-31.)
7.
Remove the DR-315 board. (Refer to 5-32-6.)
Tools
.
Cleaning cloth : 3-184-527-01
.
Cleaning fluid : 9-919-573-01
5-10. Capstan Motor Replacement