3-13
DNW-A30/A30P
DNW-30/30P
3-1. Error Message
ERROR-20 CASSETTE COMPARTMENT MOTOR LOCK
(CASS COMP MOTOR)
Description:
Malfunction of cassette compartment-up or down operation was detected.
Detectiong condition:
When no operation is completed within about six seconds after operation start
Sub error message:
None
Possible causes:
.
Cassette compartment block trouble
.
Cassette compartment motor drive circuit (DR-315 board) trouble
.
Cassette-down sensor (CL-29 board) trouble
.
Cassette-down input port (IC1 on MS-50 board) trouble
Protecting operation:
Stops the movement of the cassette compartment and reel table until a cassette
eject button is pushed.
ERROR-21 REEL SHIFT MOTOR LOCK
(REEL SFT MOTOR)
Description:
Malfunction of movement of the reel table corresponding to the cassette size was
detected.
Detecting condition:
When no operation is completed within about six seconds after operation start
Sub error message:
None
Possible causes:
.
Reel shift mechanism trouble
.
Reel shift motor trouble
.
Reel shift motor drive circuit (DR-315 board) trouble
.
Reel position sensor (PTC-71 board) trouble (S position sensor or L position
sensor)
.
Reel position input port (IC1 on MS-50 board) trouble
Protecting operation:
Stops the movement of the reel table and ejects the cassette during cassette
loading.