5-8
DNW-A30/A30P
DNW-30/30P
5-2-5. Stationary Heads Cleaning
Caution
Be careful not to damage the head surface when cleaning the stationary heads.
Tools
.
Cleaning cloth: 3-184-527-01
.
Cleaning fluid: 9-919-573-01
Procedures
1.
Clean the tape running surfaces of the AT head and CTL head in the vertical
direction with a cleaning cloth moistened with a cleaning fluid.
n
An error may occur in the playback when magnetic powder attaches to the head
gap portion of the AT head and CTL head.
Remove the magnetic powder completely during cleaning.
2.
After cleaning, wipe it with a dry cleaning cloth two or three times.
5-2. Cleaning
Stationary Heads Cleaning
AT head
CTL head
Cleaning
Exit head block
Cleaning
Entrance head block