For the operation with the upper lid removed, the air
cooling effect using the fan decreases. Complete the work
in a short time as far as possible when the unit is operated
for inspection with the upper lid removed. Blow a wind
using an electric fan so as to suppress an increase in
temperature when the work is continued for a long time
with the power turned on.
1-5. Installation Space
1-5. Installation Space
Do not block ventilation (upper lid, right side panel, lower
portion of front panel, bottom plate) and exhaust part when
installing because this unit is air-cooled by four fans.
The work area must be secured in consideration of the
service operation. Especially, the rear side must be at least
40 cm away from the walls for ventilation.
When the unit is operated on a desk or similar condition,
assure that the clearance from the upper lid and the right
side panel is at least 4 cm.
However, it is recommended that the clearance above the
unit is more than 40 cm in consideration of the service
operation.
n
Remove the feet when rack mounting.
Dimensions when Rack-Mounting
Mass DNW-A30/A30P : 34 kg
DNW-30/30P : 30 kg
577(Maximum traveling distance)
416(Rail-installed width)
427(Unit width)
Unit : mm
158
104
15.9
12.7
123.8
263.5
457.5
454
47.1
18.3
107
(70.6)
1.2
415.9
218
512.8
(454)
(47.1)
45.5
520
481
465
364
427
31.5
36.7
220
148.2
19