3-2
DNW-A30/A30P
DNW-30/30P
3-1. Error Message
Error messages are described in the order of error codes on the next page and later.
If multiple errors occur, the priority level of the error code display are as follows:
92, 93, 96, 91, 97, 98, 02, 03, 04, 05, 07, 06, 01, 09, 08, 0A, 10, 11, 12, 13, 20, 21,
22 , and 23
The “protection mode” described in this text means the servo control system auto-
matically stops the tape transport and drum motor rotation, and maintains this state.
The unit cannot be automatically recovered to the normal state when the unit once
enters the protection mode. When the protection mode is entered with the cassette
tape inserted, take out the cassette tape manually with reference to “2-12. How to
Take Out the Cassette when the Tape is Slacking”. Never turn the power on again
without taking out the cassette tape. This may damage the tape.
Error List
Code
Message
Page
Description
on time data display area
01
REEL TROUBLE
3-3
Tape slacking is detected in the threading or unthreading operation.
02
REEL TROUBLE
3-4
Tape slacking or tape breaking is detected in the SEARCH, FF, or REW mode.
03
REEL TROUBLE
3-5
Tape slacking, tape breaking, or supply or take-up reel locking is detected in the PLAY mode.
04
REEL TROUBLE
3-6
An malfunctional tape transport speed is detected in the FF or REW mode.
05
REEL TROUBLE
3-6
The malfunctional operation of the supply or take-up reel is detected during cassette
insertion.
06
TAPE TENSION
3-7
Excessive tape tension is detected in the PLAY mode.
07
CAPSTAN TROUBLE
3-7
Malfunction of capstan motor is detected.
08
DRUM TROUBLE
3-8
Malfunction of drum motor is detected.
09
TH/UNTH MOTOR
3-8
Malfunction of threading or unthreading operation is detected.
0A
THREADING TROUBLE
3-9
It is detected that the tape top processing is not completed in the threading mode.
10
HUMID
3-9
Dew condensation is detected.
11
TAPE T/E SENSOR
3-10
The tape top and tape end are detected simultaneously.
12
TAPE TOP SENSOR
3-10
Malfunction of tape top sensor is detected.
13
TAPE END SENSOR
3-11
Malfunction of tape end sensor is detected.
14
FAN MOTOR
3-12
Malfunction of cooling fan motor is detected.
20
CASS COMP MOTOR
3-13
Malfunction of cassette compartment-up or down operation is detected.
21
REEL SFT MOTOR
3-13
Malfunction of movement of the reel table corresponding to the cassette size is detected.
22
REEL POS SENSOR
3-14
The L-cassette and S-cassette positions of the reel table are detected simultaneously.
23
THREAD RING SENS
3-14
The thread end and unthread end states of the threading ring are detected simultaneously.
90
NO COMMUNICATION
3-15
Abnormality is detected in the communication between control panel (KY-364 board)
and SIO.
91
SYSTEM REFERENCE
3-15
Abnormality is detected in a system reference signal (VD).
92
INTERNAL I/F
*
Abnormality is detected in the interface between SS-63 board and other boards.
93
CPU INITIALIZE
*
Abnormality is detected during the servo system initialization at turn on the power state.
96
SY NVRAM
*
The abnormal operation of an NV-RAM (Non-volatile RAM) (SS-63 board) in
system control system is detected.
97
SV NVRAM
*
The abnormal operation of an NV-RAM (MS-50 board) in servo system is detected.
98
RF NVRAM
*
The abnormal operation of an NV-RAM (EQ-56 board) in RF system is detected.
*