5-11
DCR-IP45/IP45E/IP55/IP55E
1-2-3.
INITIALIZATION OF E, F, 1E, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1E or 1F page data, select page: 0,
address: 10, and set data: 01, then select E or F page. The 1E or 1F
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1E, 1F Page Data
Note1:
If “Initializing the E, F, 1E, 1F Page Data” is performed, all data
of the E page, F page, 1E page and 1F page will be initialized. (It
is impossible to initialize a single page.)
Note2:
If the E, F, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 1E, 1F page data
2) 54MHz/66MHz origin osc. adjustment
3) Camera system adjustments
Note3:
NTSC model: DCR-IP45/IP55
PAL model: DCR-IP45E/IP55E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1E
Adjusting Address
00 to BF
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
After about six seconds, check
that the data changes to “01”.
6
Perform “Modification of E, F,
1E, 1F Page Data”.
2. Modification of E, F, 1E, 1F Page Data
If the E, F, 1E, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1E, 1F page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1E, 1F page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1E, 1F Page
data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform “54MHz/66MHz Origin
Osc. Adjustment” of the camera
system adjustment.
Содержание DCR-IP45 - Micromv Digital Camcorder
Страница 67: ...5 1 DCR IP45 IP45E IP55 IP55E SECTION 5 ADJUSTMENTS COVER COVER ...
Страница 152: ...DCR IP45 IP45E IP55 IP55E 186 Sony EMCS Co 2002E1600 1 2002 5 Published by DI Customer Center 9 929 955 31 ...
Страница 153: ...Revision History 992995531 pdf Reverse Ver 1 0 Date 2002 05 History Official Release Contents S M Rev issued ...