5-57
DCR-IP45/IP45E/IP55/IP55E
7-4.
Mch AEQ & LMS Adjustment (VC-291 Board)
Adjust the equalizer to minimize the Mch error rate.
Mode
Playback
Signal
Recorded signal at “Preparations
Before Adjustments”
Measurement Point
Data of page: 3, address: 01
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
52 to 66, 68, 6A
Specified Value
00
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations Before Adjustments”
2
0
01
01
Set the data.
3
9
9A
64
Set the data, and press PAUSE
button.
4
9
9C
13
Set the data, and press PAUSE
button.
Mch AEQ adjustment
5
3
00
0B
Set the data, and press PAUSE
button.
6
3
01
Check that the data changes to “00”.
If the data doesn’t change to
“00”, there are errors. (Note2)
Mch LMS adjustment
7
3
00
11
Set the data, and press PAUSE
button.
8
3
01
Check that the data changes to “00”.
If the data doesn’t change to
“00”, there are errors. (Note3)
9
9
9C
10
Set the data, and press PAUSE
button.
10
9
9A
16
Set the data, and press PAUSE
button.
11
0
01
00
Set the data.
Note2:
If the data doesn’t changes to “00”, AEQ adjustment has errors.
Contents of the error is written into page: 3, addresses: 06. See the
following table.
Note3:
If the data doesn’t changes to “00”, LMS adjustment has errors.
Contents of the error is written into page: 3, addresses: 02. See the
following table.
Data of page: 3,
address: 06
01
02
03
Contents of error
Pch adjustment has errors.
Mch adjustment has errors.
Adjustment was interrupted. (Eject etc.)
8. Error Rate Check (VC-291 Board)
Mode
Camera recording and play back
Subject
Arbitrary
Measurement Point
Data of page: 3, address: 01, 02
Measuring Instrument
Adjustment remote commander
Specified Value
00
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
9
9C
Check that the data is “10”.
2
Enter the camera REC mode and
record the camera signal for
about 5 minutes.
3
Play back the recorded signal.
4
3
00
17
Set the data, and press PAUSE
button.
5
3
01
Check that the data changes to “00”.
If the data changes to “FF”,
there are errors (Note2).
Perform “AGC Adjustment and
AEQ & LMS Adjustment” again.
Note2:
If the data changes to “FF”, there are errors. Contents of the error
are written into page: 3, addresses: 02. See the following table.
Data of page: 3,
address: 02
01
02
Contents of error
LMS adjustment time out
Envelope is abnormal
Data of page: 3,
address: 02
01
02
03
Contents of error
Pch has errors.
Mch has errors.