5-53
DCR-IP45/IP45E/IP55/IP55E
2. Treel FG Duty Adjustment (VC-291 Board)
Set the Treel FG signal duty cycle to 50%.
Mode
CUE mode without a cassette
Measurement Point
Data of page: 3, address: 92
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
2C
Specified Value
70 to 90
Note1:
Don’t open the cassette compartment during this adjustment.
Note2:
When this adjustment is performed, data such as date, time and
user-set menus will be lost. After completing adjustments, reset
these data.
Note3:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
0
01
01
Set the data.
3
C
2C
80
Set the data, and press PAUSE
button.
4
9
74
01
Set the data, and press PAUSE
button.
5
9
81
01
Set the data, and press PAUSE
button.
6
9
CA
03
Set the data, and press PAUSE
button.
7
2
00
29
Set the data.
8
2
01
29
Set the data, and press PAUSE
button.
9
0
01
01
Set the data.
10
3
90
01
Set the data, and press PAUSE
button.
11
Enter the CUE mode without a
cassette.
12
3
92
When the data satisfies the
specified value, proceed to step
15.
When the data doesn’t satisfy
the specified value, proceed to
step 13.
13
C
2C
Change the data, and press
PAUSE button.
14
Return to step 11.
15
Enter the STOP mode.
16
9
74
00
Set the data, and press PAUSE
button.
17
9
81
00
Set the data, and press PAUSE
button.
18
9
CA
02
Set the data, and press PAUSE
button.
19
3
90
00
Set the data, and press PAUSE
button.
20
0
01
00
Set the data.
21
Turn off the power and turn on
again.
3. Read Clock fo Adjustment (VC-291 Board)
Set the read clock center frequency of IC1301.
Mode
Play back mode without a cassette
Measurement Point
Data of page: 3, address: 01
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
6C
Specified Value
00
Note1:
Don’t open the cassette compartment during this adjustment.
Note2:
When this adjustment is performed, data such as date, time and
user-set menus will be lost. After completing adjustments, reset
these data.
Note3:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
0
01
01
Set the data.
3
9
74
01
Set the data, and press PAUSE
button.
4
9
81
01
Set the data, and press PAUSE
button.
5
2
00
29
Set the data.
6
2
01
29
Set the data, and press PAUSE
button.
7
0
01
01
Set the data.
8
Enter the play back mode
without a cassette.
9
3
00
0F
Set the data, and press PAUSE
button.
10
3
01
Check that the data changes to
“00”.
If the data changes to “FF”,
there are errors (Time-out).
11
Enter the STOP mode.
12
9
74
00
Set the data, and press PAUSE
button.
13
9
81
00
Set the data, and press PAUSE
button.
14
0
01
00
Set the data.
15
Turn off the power and turn on