42
8 Embedded Web Server
• Name
• Trim (dB)
• Mute
The ‘Name’ input field allows the name of the physical input to be changed,
the input name can be up to 64 characters long. The audit input level can
be increased or decreased using the value in the ‘Trim’ field the value in
this field can be modified by pressing the ‘+’ and ‘-’ buttons or manually
entering a value into the input field. The value can be any whole number
from -12 to 12 and is measured in dB. If the trim is adjusted an icon will
be shown next to the name of the stream in the grid ( or ) depending
on the trim level set). An input can be muted by selecting the ‘Mute’
checkbox. If a stream is muted, a icon will be shown next to the stream
name in the grid.
Fig 8-22: ‘EQ’ Tab of the ‘Configure Physical Input’ Window
The last tab available is the ‘EQ’ tab which allows a high pass filter and low
pass filter to be applied to an input.
• The ‘High Pass Filter’ can be enabled by selecting the ‘On’ checkbox. This
removes low frequency components from a signal. The frequency of the
lowest components to be allowed can be set using the ‘+’ and ‘-’ buttons
or by typing in a value in the input field.
• The ‘Low Pass Filter’ can be enabled by selecting the ‘On’ checkbox. This
removes high frequency components from a signal. The frequency of the
highest components to be allowed can be set using the ‘+’ and ‘-’ buttons
or by typing in a value in the input field.
• The value in these two fields can be any whole number from 40 to
10000Hz.
• If a filter is set up for a stream, a icon will be shown next to the stream
name in the grid.
AVN-PA8, AVN-PA8D, AVN-PA8T and AVN-PA8TD
Fig 8-23: ‘General’ Tab of the ‘Configure Physical Input’ Window on the AVN-PA8