33
Embedded Web Server 8
Front Panel Settings
Fig 8-10: ‘Front Panel Settings’ Section of ‘Display Settings’ Webpage
Status LED Brightness
Click on the ‘+’ or ‘-’ button, or type in a value, to change the brightness of
the status LEDs on the front panel of the device, the brightness can be set
to any value from 0 to 255 with 0 being the dimmest setting and 255 being
the brightest.
Screen Saver Timeout
Click on the ‘+’ and ‘-’ buttons or type in a value, to set the time until the
screen saver is activated on the OLED and meter displays (if fitted). This is
measured in minutes and can be any whole number from 0 to 60, setting it
to 0 disables the timeout.
User Button ‘N’ Function
This allows the user to perform a function when button ‘n’ on the front
panel is pressed, where ‘n’ is 1, 2 or 3, the options available are ‘None’,
‘GPIO’, ‘Input Menu Shortcut’ and ‘Output Menu Shortcut’.
‘None’
– Pressing the associated user button does nothing.
‘GPIO’
– Allows the button to be configured in the ‘GPIO Settings’ webpage,
for example the button could be used to mute and output.
‘Input Menu Shortcut’
– Allows the user to jump into the ‘Input Channel’
menu on the OLED display which allows the user to select an input channel
to be shown in full-screen mode on the TFT metering display.
‘Output Menu Shortcut’
– Allows the user to jump into the ‘Output
Channel’ menu on the OLED display which allows the user to select an input
channel to be shown in full-screen mode on the TFT metering display.
Power Button Enabled
This option enables the power button on the front panel of the unit. When
enabled, pressing the power button will switch the unit on and off.
AC PSU Status LED
This option enables or disables the AC PSU status LED on the front panel.
DC PSU Status LED
This option enables or disables the DC PSU status LED on the front panel.