16
Copyright © 2014 SOMFY ACTIVITES SA. All rights reserved.
EN
Rollixo io
Indicator light status
Prog
Photoelectric
cells
Diagnostics
Cell fault
Consequences
Opening ok
Closing by pressing and holding down
the button within sight of the door
Actions
If no cells are installed, check that the
connector (terminals 18 and 19) is
bridged.
If cells are installed:
- Check that no obstacle is cutting across
the cell beam
- Check the position of dipswitch no.2
according to the type of cell (see
section 7.2).
- Check the cell wiring (see section 7.3).
Diagnostics
Bridged cell connector
Consequences
Opening ok
Closing by pressing and holding down
the button within sight of the door
Actions
If no cells are installed and cell connectors
are bridged (terminals 18 and 19), check
that dipswitch no.1 is set to OFF.
Diagnostics
Obstacle detection
Consequences
Remove the obstacle by full automatic
opening
Actions
Check that no obstacle is cutting across
the cell beam.
Radio
Diagnostics
Radio frame received from a recognised
transmitter
Command
Diagnostics
When a key on the keypad or a remote
control button is pressed, the indicator
OLJKWVDERYHÀDVKKROLGD\PRGHLVDFWLYH
Consequences
The product works but the keypad or
remote control cannot be used (depending
on the position of dipswitch 5) to control it.
Actions
Deactivate holiday mode (see section 8.4).
14.2 XSE transmitter
> Problem on XSE transmitter
LED1 and LED2:
/
/
Step 1: CHECK THE BATTERY
Remove the battery then press a button (PROG or MODE) to discharge
WKHUHVLGXDOHQHUJ\IURPWKHHOHFWURQLFV5H¿WWKHEDWWHU\DQGZDLWIRUWKH
DXWRPDWLFEDWWHU\WHVWWREHFRPSOHWHGDQRUDQJHOLJKWÀDVKHVWRVLJQDOWKH
test is under way - it may last up to 2 minutes).
- If LED1 and LED2 light up red for 5 seconds, replace the battery and repeat
the operations above.
- If LED1 and LED2 light up green for 5 seconds, skip to step 2.
Step 2: CHECK THE OPERATION OF THE SAFETY EDGE
Press and hold the MODE button for 3 seconds to launch safety edge
detection.
- If LED2 lights up green then the safety edge and transmitter are operating
correctly. Squeeze the safety edge and check that LED2 lights up red.
- If not, go to step 3.
Step 3: DETERMINE THE ORIGIN OF THE FAULT: XSE TRANSMITTER
OR SAFETY EDGE?
Disconnect the safety edge.
Test 1: Press and hold the MODE button for 3 seconds to launch safety
edge detection.
-
,I/('ÀDVKHVUHGIRUVHFRQGVWKHQWKH;6(WUDQVPLWWHULVRSHUDWLQJ
correctly.
- If not, the XSE transmitter is faulty.
Test 2 (optional): Press and hold the MODE button for 3 seconds to launch
safety edge detection by short-circuiting the 2 contacts on the ESE J3
FRQQHFWRUXVLQJDÀDWEODGHVFUHZGULYHU
- If LED2 lights up red for 8 seconds then the XSE transmitter is operating
correctly.
- If not, the XSE transmitter is faulty.
If tests 1 and 2 show that the transmitter is operating correctly, replace
the safety edge.
> Problem waking up the transmitter at the Up point
Important: For each test, wait until LED2 goes off to test that the transmitter
wakes up.
Test 1: Check that the XSE transmitter is working by tapping it and check that
LED2 lights up green. If not, press and hold the PROG button for 3 seconds
and retest. If the problem persists, replace the XSE transmitter.
Test 2:
2SHQ WKH GRRU IXOO\ FKHFN WKDW D EDVH PDJQHW LV ¿WWHG DQGRU WKDW
dipswitch 3 is ON, then retest.
Test 3:
,IWKHSUREOHPSHUVLVWV¿WDQXSSHUPDJQHWDQGVHWGLSVZLWFKRQWKH
XSE transmitter to ON then retest.
If the problem persists, replace the XSE transmitter.
15 - TECHNICAL DATA
*(1(5$/63(&,),&$7,216
Power supply
230 V - 50-60 Hz
Electrical insulation
Category 1
Maximum motor output
Safety fuse for motor and integrated
lighting
230 V - 1250 W
5 AT - 250 V - spare fuse supplied
Climatic operating conditions
- 20°C/+ 60°C - IP 20
Somfy radio frequency
io 868 - 870 MHz
< 25 mW
Number of storable remote controls
30
CONNECTIONS
Mains power supply cable
2 m - IEC sheet (phase-neutral-earth)
Integrated courtesy lighting
E14 - 1.4W - 230V LED bulb
Safety inputs
3 inputs for:
- Wired safety edge: optical, resistive
- Fall protection device
- Photoelectric cells
Self-test output for safety devices
For cells
Wired control input
NO dry contact - sequential operation
Orange light
24V - 4W max.
Alarm siren output
Yes
OPERATION
Control buttons
Up-Stop-Down buttons in the control
panel
Automatic closing mode
Yes
Maintenance assistance
Real time status with 5 indicator lights