11
Copyright © 2015 Somfy SAS. All rights reserved.
EN
Elixo 500 3S io
terminals
terminal
indications
Connection
Comments
1
2
L
N
230 V power supply
Note: Earth connection available on the motor body
3
4
L
N
Transformer primary supply output
5
6
N
L
230 V lighting output
Max. power 500 W
Protected by 5A time-delay fuse
7
8
Conductor
Braid
Aerial
9
10
11
Contact
Shared
Contact
PEDESTRIAN/CLOSING control input
COMPLETE/CLOSING control input
PEDESTRIAN/OPENING cycle programmable
COMPLETE/CLOSING cycle programmable
12
13
Shared
Contact
Auxiliary contact output
24 V, 1.2 A outage
Safety Extra Low Voltage (SELV)
14
15
Contact
Shared
Safety input 3 - programmable
16
Contact
Safety test output
17
18
Contact
Shared
Safety input 2 - safety edge
Only compatible with a dry contact safety edge
19
20
21
22
Contact
Shared
24 V
0 V
Safety input 1 - Cells
Safety device power supply
BUS compatible (see parameter table)
Used to connect RX cell
Permanent if autotest not selected, controlled if autotest selected
23
24
24 V
0 V
24 V accessories power supply
1.2 A max for all accessories on all outputs
25
26
24 V - 15 W
0 V
24 V - 15 W orange light output
27
28
9 V - 24 V
0 V
9 V or 24 V low voltage supply input
Compatible batteries 9.6V and 24V
At 9 V, degraded operation
At 24 V, normal operation
29
30
31
EOS O
Shared
EOS F
Motor end limit
32
33
1
2
Motor
34
35
24VAC
Transformer
gEnEraL wIrIng dIagraM
TX
RX
24 Vdc
230 V
50 Hz
... ...
230 V
500 W max.
0.75 mm²
0.75 mm²
1.5 mm²
1.5 mm²
Ant.
7
8
Sec Prog
12
13
Aux
14
15
9
10
11
Sec BP
Test
16
17
18
23
24V dc
-
24
+
-
+
19
21
22
24V Cell
-
20
+
Sec Cell
EOS O EOS F
29
30
31
24Vac
34 35
Flash
25
26
32
33
Motor
M1
27 28
Batt.
+
-
Lamp
5
6
L N
230Vac
1
2
230Vac
3
4
Motor end limit
Motor
transformer