9
Copyright © 2015 Somfy SAS. All rights reserved.
EN
Elixo 500 3S io
quICK COMMISSIOnIng
Memorising the Keygo io remote controls for operation in complete opening mode
2 s
h0
add h0
f0
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
[1].
Press and hold the "
prOg
" button (2 s) on the programming interface.
The screen displays "F0".
[2].
Press the outer left and right buttons on the remote control together.
The remote control indicator light flashes.
[3].
Press the button of the remote control that will open the gate fully.
The screen displays "Add".
[1]
[2]
[3]
Self-learning
Self-learning allows the gate's speed, maximum torque and slowdown zones to be adjusted.
- Auto programming the gate's travel is essential when commissioning the motor.
- The gate must be in the intermediate position before self-learning starts.
-
During self-learning, the obstacle detection function is not active. Remove any objects or obstacles and do not allow any
persons near or inside the operating range of the motorisation.
- To carry out an emergency stop during self-learning, use a stored remote control or press one of the interface buttons.
Start self-learning
[1].
Press and hold the "
SEt
" button (2 s).
Release the button when the screen displays "
h1
".
[2].
Press "
OK
" to start self-learning.
Self-learning must start with the gate being opened.
The gate performs two complete Opening and Closing cycles.
Self-learning correct
Self-learning incorrect
2 s
h0
h1
h2
h4
h2
h4
h0
C1
[1]
[2]
2 s
...
...
•
If self-learning starts when the gate is closed, stop the self-learning in progress
(press a control button: motor electronics, memorised remote control, wired
control point, etc.), move the slide as shown opposite, then restart self-learning.
•
If self-learning is correct, the display indicates "
C1
".
•
If self-learning has not completed correctly, the display indicates "
h0
".
At the end of installation, it must be checked that the limitation of forces complies with appendix A of the standard EN 12 453.