Elixo 500 3S io
Code description
values (bold = default)
Setting
completed Comments
p03
Pedestrian cycle
operating mode
0: identical to complete cycle
operating mode
The pedestrian cycle
operating mode
parameters can only
be set if P01 = 0 to 2
The P03 = 2
operating mode is
not compatible with
remote control using a
TaHoma unit.
Pedestrian cycle operating mode is identical to the complete
cycle operating mode selected.
1: without automatic closing
If P01=1, the gate does not close automatically following a
pedestrian opening command.
2: with automatic closing
Operation in automatic closing mode is only authorised if the
photoelectric cells are fitted. i.e. P07=1 to 4.
Irrespective of the value of P01, the gate does not close
automatically following a pedestrian opening command.
The automatic closing time delay can be programmed in
parameter "
p04
" (short time delay) or parameter "
p05
" (long
time delay).
p04
Short automatic closing
time delay in pedestrian
cycle
0 to 30 ( value x 10 s = time delay
value)
2: 20 s
If value 0 is selected, the gate immediately closes automatically.
p05
Long automatic closing
time delay in pedestrian
cycle
0 to 99 ( value x 5 min = time delay
value)
0: 0
Value 0 must be selected if the short automatic closing time delay in pedestrian cycle
is active.
p06
Pedestrian opening
amplitude
1 to 9
1: 80 cm
1: minimum pedestrian opening
...
9: maximum pedestrian opening (approximately 80% of the gate's total travel)
p07
Cell safety input
0: inactive
1
:
active
2: active with autotest via test
output
3: active with autotest via power
supply switching
4: bus cells
0: the safety input is not taken into account.
1: safety device without autotest; it is essential to check that it is operating correctly
every 6 months.
2: the autotest is run on the device for each operating cycle via the test output, reflex
photocell application with autotest.
3: the autotest is run on the device for each operating cycle via power supply switching
of the cell power supply output (terminals 21 and 22).
4: bus cells application.
p08
Safety edge safety
input
0: inactive
1: active
2: active with auto-test
0: the safety input is not taken into account.
1: safety device without auto-test.
2: the autotest is run on the device for each operating cycle via the test output.
p09
Programmable safety
input
0: inactive
1
:
active
2: active with autotest via test
output
3: active with autotest via power
supply switching
0: the safety input is not taken into account.
1: safety device without auto-test.
2: the autotest is run on the device for each operating cycle via the test output.
3: the autotest is run on the device for each operating cycle via power supply switching
of the cell power supply output (terminals 21 and 22).
p10
Programmable safety
input - function
0: active closing
1: active opening
2: active c ADMAP
3: all movement disabled
0: the programmable safety input is only active when closing.
1: the programmable safety input is only active when opening.
2: the programmable safety input is only active when closing and, when activated, the
gate cannot be opened.
3: emergency stop application; if the programmable safety input is activated, the gate
cannot be moved.
p11
Programmable safety
input - action
0: stop
1: stop + partial reversal
2: stop + complete reversal
0: emergency stop application,
compulsory if p10=3
disabled if a safety edge is connected to the programmable safety input.
1: recommended for a safety edge application.
2: recommended for a cell application.
p12
Orange warning light
0: no warning
1: with 2 s warning prior to
movement
If the gate opens onto a public path, the "with warning" configuration must be selected:
P12=1.
p13
Area lighting output
0: inactive
1: controlled operation
2: aut controlled
operation
0: the area lighting output is not taken into account.
1: the area lighting is remotely controlled.
2: the area lighting is remotely controlled when the gate is stationary
+ the area lighting comes on automatically when the gate is moving, and remains
on when it stops moving for the duration of the time delay programmed in parameter
"
p14
".
p13=2 is compulsory for operation in automatic mode
.
p14
Area lighting time delay 0 to 60 ( value x 10 s = time delay
value)
6: 60 s
If value 0 is selected, the area lighting goes out as soon as the gate stops moving.
p15
Auxiliary output
0: inactive
1: automatic: gate open indicator
light
2: automatic: timed bistable
3: automatic: one-touch
4: controlled: bistable (ON-OFF)
5: controlled: one-touch
6: controlled: timed bistable
0: the auxiliary output is not taken into account.
1: the gate indicator light is off when the gate is closed, flashing when the gate is
moving and on when the gate is open.
2: output activated when movement starts, during movement then deactivated at the
end of the time delay programmed in parameter "
p16
".
3: one-touch at contact when movement starts.
4: operation changes as follows each time the memorised button on the radio control
point is pressed: ON, OFF, ON, OFF...
5: one-touch at contact by pressing the memorised button on the radio control point.
6: output activated by pressing the memorised button on the radio control point then
deactivated at the end of the time delay programmed in parameter "
p16
".
p16
Auxiliary output time
delay
0 to 60 ( value x 10 s = time delay
value)
6: 60 s
The auxiliary output time delay is only active if the value selected for P15 is 2 or 6.