![SOMFY Elixo 500 3S io Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/somfy/elixo-500-3s-io/elixo-500-3s-io_installation-instructions-manual_1317922076.webp)
23
Copyright © 2015 Somfy SAS. All rights reserved.
EN
Elixo 500 3S io
dIagnOStICS
Operating code display
Code
description
Comments
C1
Awaiting command
C2
Gate opening
C3
Awaiting gate closure
Automatic closing time delay P02, P04 or P05 in progress.
C4
Gate closing
C6
Detection in progress for cell safety
Displayed during a movement request or during movement when detection is in progress on the safety input.
The display appears for as long as detection is in progress on the safety input.
C7
Detection in progress for safety edge
safety
C8
Detection in progress for programmable
safety
C9
Detection in progress for emergency
stop safety
C12
Reinjecting current
C13
Safety device autotest in progress
Displayed while the autotest is running on the safety devices.
C14
Permanent complete opening wire
control input
Indicates that the complete opening wire control input is permanently activated (contact closed). Commands coming
from the radio remote controls are then disabled.
C15
Permanent pedestrian opening wire
control input
Indicates that the pedestrian opening wire control input is permanently activated (contact closed). Commands coming
from the radio remote controls are then disabled.
C16
BUS cell programming refused
Check that the BUS cells (wiring, alignment, etc.) are operating correctly
Cc1
9.6 V power supply
Displayed during operation with 9.6 V backup battery
Cu1
24 V power supply
Displayed during operation with 24 V backup battery
programming code display
Code
description
Comments
h0
Awaiting setting
Pressing and holding the "
SEt
" button for 2 seconds starts self-learning mode.
hc1
Awaiting s 9.6 V power supply
Displayed during operation with 9.6 V backup battery
hu1
Awaiting s 24 V power supply
Displayed during operation with 24 V backup battery
h1
Awaiting start of self-learning
Pressing the "
OK
" button starts the self-learning cycle.
Pressing the "
+
" or "
-
" button allows the motor to be controlled in forced operation mode.
h2
Self-learning mode - opening
h4
Self-learning mode - closing
f0
Awaiting remote control memorisation for
operation in complete opening mode
Pressing a button on the remote control allocates this button to the motor complete opening control.
Pressing "
prOg
" once more switches to "awaiting remote control memorisation for operation in pedestrian opening
mode:
f1
".
f1
Awaiting remote control memorisation for
operation in pedestrian opening mode
Pressing a button on the remote control allocates this button to the motor partial opening control.
Pressing "
prOg
" once more switches to "awaiting remote lighting control memorisation:
f2
".
f2
Awaiting remote control memorisation
for remote lighting control
Pressing a button on the remote control allocates this button to the remote lighting control.
Pressing "
prOg
" once more switches to "awaiting auxiliary output control memorisation:
f3
".
f3
Awaiting remote control memorisation
for auxiliary output control
Pressing a button on the remote control allocates this button to the remote lighting control.
Pressing "
prOg
" once more switches to "awaiting remote control memorisation for operation in complete opening
mode:
f0
".