Elixo 800/1300/2000
14
Copyright © 2011 Somfy SAS. All rights reserved.
EN
9. ParamEtEr sEttiNG
operation
setting
description of operation
operating mode of
photoelectric cells
12
ON
SW
2
Photoelectric cell input active only for closing
: if the cells are obstructed in
the closing phase, the gate will stop and then reopen. If they are obstructed when
opening, the gate will continue to open.
1
2
ON
SW2
Photoelectric cell input active when opening and closing
: if the cells are
obstructed when opening, the gate will stop and start again when the cells are no
longer obstructed. if the cells are obstructed in the closing phase, the gate will stop
and then reopen.
activate/deactivate
the automatic
closing function with
movement in front of
the cells
1
2
ON
SW
2
automatic closing function deactivated.
1
2
ON
SW
2
automatic closing function activated
: moving in front of the cells causes the gate
to close immediately.
impact against an
obstacle
1
23
4
ON
SW
1
obstacle detection activated
: Impact against an obstacle, in both opening and
closing phases, is detected by an encoder system which blocks the gate and
reverses movement by 10 cm -see page 5-
12
3
4
ON
SW
1
obstacle detection deactivated
: Impact against an obstacle is not detected and the
motor continues driving.
If obstacle detection is deactivated, use other safety systems (e.g.:
safety edge) in accord with the standards in force.
It is the installer's responsibility to ensure that the automatic installation
and its operation are compliant with the standards in force.
activating/deactivating
orange light warning
12
3
4
ON
SW
1
Warning deactivated
: the orange light comes on when the gate opens.
123
4
ON
SW1
Warning activated
: the orange light comes on 3 seconds before the gate opens.
method of operation
12
3
4
ON
SW
1
sequential mode: 4 steps
During opening: sending an open/close command stops motion, a successive
command causes the gate to close.
During closure: sending an open/close command stops motion, a successive
command causes the gate to open.
During the gate open pause: an open/close command cancels the pause time and
causes the gate to close immediately.
1
2
3
4
ON
SW1
semiautomatic mode: 3 steps
During opening: if an open/close command is sent, it is ignored and the gate
continues to open.
During closure: sending an open/close command blocks the gate for a few seconds
and then it opens again.
During the gate open pause: an open/close command cancels the pause time and
causes the gate to close immediately.
do Not usE
1
2
3
4
ON
SW
1
leave in off position.
9.1. setting the operating modes
The operation parameters are set using micro switches
SW1 and SW2.
During the setting operations, the motor must be off.
When modifying the settings, it is necessary to switch the control unit off and on again to activate these new
settings.
O
LAVOR
PAUSA
PROG
PROG
+
-
RE
G
10
9
18
19
20
21
22
START
PED
STOP
FOTO
FCA
FCC
COSTA
DL10
DL11
ENCODER
DL12
1
2
3
4
5
6
7
8
SOG/4
A
F1
F2
O
LAVOR
AA
PAUSA
PROG
PROG
+
-
R
EG
21
22
START
PED
STOP
FOTO
FCA
FCC
COSTA
DL10
DL11
EN
C
O
D
ER
DL12
2
SO
G
/4
A
F1
F2
1
3
4
5
6
7
8
10
9
19
20
18
SW1
SW2
O
N
O
N