Table 14. Meg Test tab description
Name
Description
Add Measurement
Adds a new line to the table. The current date and time is
listed, and the line is assigned an ID number.
Delete Measurement
Deletes the currently selected measurement from the list.
Limit Resistance
Enter the minimum acceptable value of insulation
resistance. Any measured values that are below this limit
will be highlighted in red in the table.
Selection box
Selects or clears the measurement of interest.
Date/Time
Displays the date and time each measurement was
added to the table.
Array Location
Accesses the system tree for selecting the location at
which the measurement was made.
ID
Automatically assigned identification number. The ID
number increments by one count each time a
measurement is added.
Resistance
The measured value of insulation resistance in
megohms. Click in this field to enter the value manually.
Voltage
The voltage at which the insulation resistance was
measured. Click in this field to enter the value manually.
Description
Optional description of the device under test.
Description of the Exported I-V Data File
This section describes the organization of the .csv (comma separated value) file that is
created in your hard drive when you export measurements from the PVA software.
PV Analyzer users typically analyze their measurement results using the Solmetric I-V
Data Analysis Tool (DAT), which automates the analysis and reporting process. To use
the DAT, you will first export your Project data from the PV Analyzer, and then import it
into the DAT.
Содержание PVA-1000S
Страница 12: ...xii This page is intentionally left blank ...
Страница 68: ...1 Getting Started 2 56 Over Voltage Warnings ...
Страница 116: ......
Страница 128: ......
Страница 133: ...7 Interpreting Measured I V Curves 7 5 5 4 Rounder knee 6 ...
Страница 148: ......
Страница 152: ...8 Translation of I V Data to Standard Test Conditions 8 4 This page is intentionally left blank ...