5 Troubleshooting PVA Operation
5-4
also blinks rapidly when it is not connected to the PC via WiFi. Make sure that the I-V
Unit is turned on and is within wireless range.
“No WiFi connection” (PVA-1500xx only)
This message appears when the PC WiFi network adapter is turned off. Turn on the Wifi
adapter and connects to the PVA1500_yyyyyy hotspot.
“Searching for SolSensor” message and/or “ ---- ” in SolSensor data display
With the SolSensor, these messages appear in the SolSensor data display area when the
SolSensor does not have a wireless link to the I-V Unit (via Wireless USB Interface for
PVA-1000S and PVA-600+ and via WiFi for PVA-1500xx). Make sure the SolSensor is
turned on and that it is within wireless range. Obstructions in the line-of-sight can also
reduce wireless range.
The SolSensor may recover by performing a hard reset of the SolSensor and I-V unit by
holding down the power button for 5 seconds on each.
With the SolSensor 300xx it is also possible that it is not properly “paired” to your I-V
unit. The SolSensor 300xx units are paired at the factory to the specific I-V unit that
shipped with your SolSensor. If you have a new SolSensor that was never paired to your
I-V unit, or it has lost its pairing, it may be re-paired to the I-V unit by following the
steps in
Operational States of the PVA-1500xx I-V Measurement Units
Troubleshooting by Symptom
"No I-V Measurement Unit" message
This message in the Status indicator (upper right corner of measurement screen) means
that the I-V Measurement Unit is either turned off or is out of wireless communication
range.
The message will also appear if the Network ID number of the I-V Measurement Unit
and Wireless USB Adapter do not match. See Your Wireless Network for details.
Reduced wireless range can be caused by objects (especially metal) blocking the line-of-
sight from PC to I-V Measurement Unit, or by placing either the PC or the I-V
Measurement Unit on top of or near metal objects like metal roof surfaces, equipment
housings and so on. The corrective action is to clear the line-of-sight and to raise the
equipment above the metal surfaces. If these steps do not solve the problem, move the PC
closer to the I-V Measurement Unit.
SolSensor parameter values are not displayed
Содержание PVA-1000S
Страница 12: ...xii This page is intentionally left blank ...
Страница 68: ...1 Getting Started 2 56 Over Voltage Warnings ...
Страница 116: ......
Страница 128: ......
Страница 133: ...7 Interpreting Measured I V Curves 7 5 5 4 Rounder knee 6 ...
Страница 148: ......
Страница 152: ...8 Translation of I V Data to Standard Test Conditions 8 4 This page is intentionally left blank ...