2-39
Table 8 describes the operational states of these instruments.
Table 8. Pushbutton LED table for the PVA-1500xx I-V Units
I-V Unit State
LED Behavior
Pushbutton
Behavior
Details
Off
Off
Press once to
turn on.
Any state
Press 3x to turn
off I-V Unit.
Network search
Rapid flashing
Press 3x to turn
off I-V Unit.
Attempting to
reconnect the I-V Unit
with the PC
Paused
Very slow flashing,
once every 3 seconds
Press once to
enable
measurements or
3x to turn off I-V
Unit.
I-V Unit turns off in 15
minutes to conserve
battery.
Connected to PC,
sweep enabled
Steady ON
Press once to
pause, or 3x to
turn off I-V Unit.
Battery being
charged
Slow flashing,
changing to steady ON
when fully charged
Charging indication is
available in PVA-
1500V2/V3 only.
Measurements cannot
be taken while
charging.
Re-pairing with
SolSensor
Five flashes and a
longer pause, repeated
Press 5x in rapid
succession to
initiate the re-
pairing.
This functionality is
available in the PVA-
1500V2/V3 only. After
you see groups of five
flashes on the I-V Unit,
press SolSensor’s
LED button 5x in rapid
succession to initiate
re-pairing.
To reset IV-Unit or SolSensor
: Hold the pushbutton down 5 seconds and then release.
When you turn the PVA-1500xx I-V Measurement Unit on by pressing the pushbutton
once, the LED blinks rapidly until it connects with your PC. Once it connects, the LED
stays steadily lighted.
Before connecting the I-V Unit’s test leads to the PV circuit, press the pushbutton once to
pause the I-V Unit. This prevents accidentally triggering a measurement while you are
making connections. During the paused state, the LED will flash with long pauses to
show that the I-V Unit is still available. If the I-V Unit is left in the paused state for
Содержание PVA-1000S
Страница 12: ...xii This page is intentionally left blank ...
Страница 68: ...1 Getting Started 2 56 Over Voltage Warnings ...
Страница 116: ......
Страница 128: ......
Страница 133: ...7 Interpreting Measured I V Curves 7 5 5 4 Rounder knee 6 ...
Страница 148: ......
Страница 152: ...8 Translation of I V Data to Standard Test Conditions 8 4 This page is intentionally left blank ...