CSE-M53N User Manual Ver. 2.5
Sollae Systems Co., Ltd.
- 28 -
http://www.ezTCP.com
4.3
Comparison with each mode
Name
Serial port
Serial type
Normal
configured value
RS232/RS422/RS485
Serial Configuration
115,200/N/8/1
RS232/RS422
ISP
-
-
Table 4-1 comparison of each mode
4.4
Normal Mode
In normal mode, there are four connection types to communication with a remote host.
Mode
Description
TCP Server
Wait connection request from TCP clients (Passive Connection)
TCP Client
Send connection request to a TCP server (Active Connection)
AT Command Control connections by AT commands (Active / Passive Connection)
UDP
Communicate in block units without connection
Table 4-2 comparison of communication mode
Name
Protocol Connection
Modifying
software of
serial devices
Serial
configuration
Topology
TCP Server
TCP
Passive
-
Unavailable
1:1
TCP Client
Active
-
Unavailable
1:1
AT Command
Either
Required
Available
1:1
UDP
UDP
-
-
Unavailable
N:M
Table 4-3 comparison of four communication modes