Once answered, press the button “CELLULAR” at the 

console to enter the audio. The audio enters to the con-

sole through “HYBRID” fader.

Like with the conventional lines, you can listen in previ-

ous that call; to engage in a dialog pressing TALK; to 

leave waiting to the caller (HOLD) and to send the call 

to the air opening the fader (AIR). 

If you want to call from the cell phone, it is possible to 

make the call and to connect soon the “free hands” ca-

ble to the telephone. Or it can contact with the connec-

ted telephone, listening to the audio by CUE and pres-

sing TALK to engage in a dialog (fader closed). 

TAKE IN MIND

EXTERNAL HYBRID AND CELL PHONE CANNOT BE ON AIR 

AT THE SAME TIME

 

CELL PHONE BUTTON MUST BE RE-

LEASED IN ORDER TO USE EXTERNAL HYBRID

THE AUDIO FROM THE CELL PHONE IS NOT SENT TO THE 

EXTERNAL HYBRID IN ANY CASE. THERE IS NO CONFE-

RENCE   BETWEEN   CELLULAR   AND   THE   EXTERNAL   HY-

BRID.

 If you need this feature, please use an external hybrid 

with Cell Phone connection, like Solidyne HA204.

3.2.2 Return to phone line

Most of the existing telephone hybrids on the market 

today, were designed over 30 years ago for analogue 

telephone exchanges (PBX)   Solidyne hybrids, howe-

ver, have been recently designed for private or public 

telephone exchanges today, which are fully digital. The 

new technology Hybrids are recognized because they 

have no control of air return level to phone line. This is 

because inside the hybrid Solidyne uses an audio pro-

cessor for return signal that includes  AGC, peak limiter 

& audio signal filtering. Therefore the return is automa-

tically adjusted during the transmission and its level is 

the maximum allowed by the modern digital telephone 

exchanges. 

If you want to check the return level to phone line, you 

must use a oscilloscope to be placed in parallel with the 

telephone line and must verify that the signal is 2 volts 

peak to peak. 

Please note that above this level the return can produ-

ce problems that will cause intermodulation distortion in 

the audio signal that goes to  air. So in Solidyne hybrids 

we use a processed return channel,  to avoid distortion 

at the on-air  signal. There are hybrids manufacturers 

that maintain the return control level as they did in the 

past. This allow operators to adjust "by hunch"  this cri-

tic level. This makes the voices of the reporters and  in-

terviewed people  distorted or with coloration.

In Solidyne obviously, we keep a high  grade of excel-

lence   in the audio quality of the hybrid on-air sound. 

And that quality do not depend on the operator set-

tings. Note that the Solidyne Hybrid on- air audio qua-

lity of the local journalists is ever perfect and without 

any coloration. 

To achieve this level of quality we use a narrow-band 

return filter. Then   the return signal is limited to the 

band 400 – 2.200 Hz in order not to distort the signal 

to the air. This narrow band intelligibility remains high 

(due to processing) but occasionally may seem to the 

remote people that it  "has little volume" because his 

band is narrow. This should not worry because it is a 

subjective sensation that does not affect the intelligibi-

lity of speech. 

3.2.3

Rejection setup (Null)

This adjustment is only for LAND lines. The rejection 

factor expresses the capacity of the hybrid to avoid that 

the transmitted signal returns distorted to the air. Whi-

chever greater it’s this factor more “clean” will be the 

sound quality of the local speaker on the air. In order 

set the rejection, proceed as following:

1.

Make a calling through 

one

 

hybrid of the console. 

2.

Listening to the voice of the local speaker from the 

PGM 

monitor

, carefully turns the preset “Null” until reducing to 

zero the distortion superposed to the speaker’s voice.

 

Ple-

ase make this adjust when the console is installed.

3.2.4 Managing conferences

The   conference   can   be   made   establishing   the   calls 

from the associate telephones and sending them to the 

air by pressing “Line 1” and “Line 2” on the console. 

Once taken the callings in the console, you must hang 

the telephones.
Let us suppose that the speaker is engaging in a dialog 

with an interviewed person who called (or he was cal-

led) by the line #1; and you want to add to the conver-

sation another person. Using the associate telephone, 

you make the call from the line #2. Once contacted; 

press the button “line 2”. The calling will be DIRECTLY 

on the air.  Remember to hook the telephone.
In the same way proceed with the cell phone.

3.2.5 Vox-IP communications (Skype)

While not the hybrid channel who provides communi-
cation via Internet, we will explain here the procedu-
re for communication using VoIP software like Skype 
or similar. 

ATTENTION

USB 7 CANNOT BE USED IF CHANNEL USB 6 IS NOT 
CONNECTED; 

since it is slave of channel 6. Both chan-

nels can be connected to the same computer.

WHEN   TWO   PCs   ARE   CONNECTED;

  CONSIDER 

THAT CHANNEL 7 CANNOT BE USED IF THE COMPU-
TER  CONNECTED  TO CHANNEL  6  IS

 

POWER OFF. 

Usually channel 6 is used with the air PC; which is 24 Hs 
operative.

SOLIDYNE

D·816

 broadcast console

Page 17

Содержание D 816

Страница 1: ...Buenos Aires Argentina Phone 54 11 4702 0090 e mail info solidynepro com Fax 54 11 4702 2375 Web site www SolidynePRO com USB INPUTS OUTPUTS DIRECT HARD DISK RECORDING ON AIR compact console User s m...

Страница 2: ...Page 2 D 816 broadcast console SOLIDYNE...

Страница 3: ...ER 3 Using the console 15 3 1 Overview 15 3 1 1 Quick checking 15 3 2Using the hybrid channel 16 3 2 1 Operation 16 3 2 1 1 Use with a CELL PHONE 16 3 2 2 Return to phone line 17 3 2 3 Rejection setup...

Страница 4: ...Page 4 D 816 broadcast console SOLIDYNE...

Страница 5: ...put Four LINE channels allow connecting up to 8 sour ces Channels 4 and 5 manages balanced analogical inputs whereas channels 6 and 7 are digital with di rect connection to the computer via USB ports...

Страница 6: ...hen opening the channels MIC 1 and or MIC 2 channel MIC 3 does not activate the tally since it can operate as line or microphone The LOAD DOES NOT HAVE TO EX CEED the 120 mA two Solidyne AIR lights If...

Страница 7: ...of equipment s to the AC line the seconds ones are generated by communications transmitters or industrial equipment If these signals penetrate into audio lines with sufficient intensity can surpass th...

Страница 8: ...s and out puts connectors Take in mind that good connections offer safe and free of faults operation By this reason we recommend you take it the time necessary to make the connections care fully and u...

Страница 9: ...uter in digital format the program and recording outputs please see 2 2 3 2 USB Outputs VERY IMPORTANT USB 7 CANNOT BE USED IF CHANNEL USB 6 IS NOT CONNECTED since it is slave of channel 6 In order to...

Страница 10: ...in level control or as a more professional solution to mount a control on the speaker s table A potentiometer of 2 x 1KOhm will be right to manage the level In this case the level control of the conso...

Страница 11: ...ode denominated 4 wires different from the telephone lines 2 wires In almost all models microphone and speaker dis connects while the cell phone is used in free hands mode Please refers to the user ma...

Страница 12: ...s of the console There are three signals of control channels of mi crophone 1 and 2 they handle the same output channel Line 5 and Line 6 These three control outputs are of open collector type They wo...

Страница 13: ...SOLIDYNE D 816 broadcast console Page 13...

Страница 14: ...2 2 10 Recommended grounding for a FM station Page 14 D 816 broadcast console SOLIDYNE...

Страница 15: ...E level unbalanced Then it can be used as MIC or LIN input The three microphone channels can be routed to the processing stage 4 bands EQ and compressor with independence The analog line channels mana...

Страница 16: ...taken the talk back MIC is sent to both callers You will engage in a dialog in mode half duplex When the private dialog finalizes you can raise the fa der HYBRID towards the position HOLD that sends...

Страница 17: ...we keep a high grade of excel lence in the audio quality of the hybrid on air sound And that quality do not depend on the operator set tings Note that the Solidyne Hybrid on air audio qua lity of the...

Страница 18: ...cell phone The D 816 allows maximum flexibility to generate a virtual forum between journalists and interviewees very far apart For this proceed as follows 1 Keep the controls like previous descripti...

Страница 19: ...t will be listened in monitors and headphones The assignments for Studio and Control Room are independent The options are PGM to listen the console output REC allows the listening of the channels that...

Страница 20: ...ol Room monitors will be muted to avoid feedbacks loops Your voice will be listened inside the Studio by the left channel The right channel stays with the on air audio so that speakers and journalists...

Страница 21: ...processor stage EQ with both buttons released If both buttons are pressed the signal is only sent to PGM Enable disable the phantom power 48V for all mic channels Main fader To enable the microphones...

Страница 22: ...er below this level the signal from the previous stage must be very high and the peaks will be clipped 3 4 2 Processing Each MIC channel can be sent directly to the air PGM or the processing stage EQ...

Страница 23: ...rams D 816 consoles have two stereo output channels The main channel is denominated Program PGM and used for the On Air signal For recording REC is used You can make recor dings while simultaneously t...

Страница 24: ...IGNAL EX CEPT WAVE AND GAIN CONTROL MAIN When the work is finished reset all the controls to the original position to return the console to the nor mal way of operation 3 6 2 Recording calls The D 816...

Страница 25: ...ember that the rear connec tors are not designed for daily use avoid connection of headsets directly to console When the operator s changes frequently its headsets use an external pat ch panel to avoi...

Страница 26: ...This page was left empty intentionally Page 26 D 816 broadcast console SOLIDYNE...

Страница 27: ...control to the minimum and increase the input level up to 18 dBm move the fader until ob tain 4 dBm at the output without visible clipping Increase the gain with the main fader until obtaining 15 dBm...

Страница 28: ...t MIC and PGM in the channel under test Enable the module by pressing AIR Set the main fader to 10 dB Change the gain control until obtaining 15 dBm at the console output this is the reference level R...

Страница 29: ...ompression ratio 2 dB variation for 15 dB change MIC level Noise MIC input EIN 120 dBu 150 ohms LINE input S N 70 dBA Dynamic range From Line to PGM 90 dBA CD quality Crosstalk PGM REC 65 dBA 1 kHz Di...

Отзывы: