10.0
Troubleshooting
and
Inverter
Messages
Although
the
inverter
is
designed
for
many
years
of
power
production,
there
may
be
instances
where
error
messages
are
displayed
on
the
LCD.
This
table
can
be
used
to
help
identify
the
error
and
resolve
it.
Type
Name
Definition
Possible
Causes
Recommended
Solutions
Alarm
1.
TempSensorErr
Abnormal
temperature
reading
1.
Internal
temperature
sensor
is
making
poor
contact.
1.
Verify
temperature
reading
off
of
the
display.
2.
Switch
off
the
inverter’s
internal
disconnects.
3.
Switch
the
Inverter
back
on.
4.
If
error
does
not
clear,
contact
Solectria
Customer
Service.
2.
Temperature
sensor
is
damaged.
Alarm
2.
SPICommErr
Inverter’s
internal
communication
failure
1.
Poor
connection
of
the
inverter’s
internal
communication
connector.
1.
Observe
for
5min
and
see
whether
the
alarm
is
cleared
automatically.
2.
Switch
off
the
inverter’s
internal
disconnects.
3.
Switch
the
Inverter
back
on.
4.
If
error
does
not
clear,
contact
Solectria
Customer
Service.
Alarm
3.
IntFanErr
Inverter’s
internal
fan
(can’t
be
seen
externally)
is
not
operating
properly
1.
Fan
service
life
has
expired.
1.
Observe
for
5min
and
see
whether
the
alarm
is
cleared
automatically.
2.
Switch
off
the
inverter’s
internal
disconnects.
3.
Switch
the
Inverter
back
on.
4.
If
error
does
not
clear,
contact
Solectria
Customer
Service.
2.
Fan
connector
is
making
a
poor
connection.
Alarm
4.
ExtFanErr
One
of
the
three
external
fans
is
not
operating
properly
1.
Fan
is
blocked.
1.
Observe
for
5min
and
see
whether
the
alarm
is
cleared
automatically.
2.
Switch
off
the
inverter’s
internal
disconnects.
3.
Check
the
fan
blades
for
debris.
Содержание PVI 23TL
Страница 136: ...SMA Solar Technology www SMA Solar com ...