SYSTEMS AND SCHEDULED MAINTENANCE
34
Operator’s Manual Marine Diesel Engines
Revision 0. 05/2016
Type 2 installation. When between water injection point of wet exhaust and waterline
there is less than 150 mm or the point of injection is below waterline.
The wet exhaust is the engine’s standard equipment. If you want dry exhaust, which is an
optional equipment, contact with our dealers
MAINTENANCE TASK. AIR FILTER INSPECTION
Engine is provided with an intake air filter. Examine the element
and housing for damage. Replace the complete air filter if necessary.
It is important to ensure that the combustion air is freely
supplied and freely expelled from the area.
MAINTENANCE TASK. EXHAUST GAS, NOISE AND VIBRATIONS INSPECTION
Inspect the exhaust system components for cranks, leaks and corrosion.
EXHAUST SYSTEM INSPECTION POINTS
1.
Check the hoses for softness, cranks or dents. Replace the hoses as needed.
2.
Check for corroded or broken metal parts and replace them as needed.
3.
Check for loose, corroded or missing clamps. Tighten or replace the hose clamps
and/or hangers as needed.
4.
Check that the exhaust outlet is unobstructed.
5.
Visually inspect the exhaust system for exhaust leaks. Check for carbon or soot
residue on exhaust components. Carbon and soot residue indicates an exhaust leak.
Seal leaks as needed.
Содержание SM-82
Страница 1: ...INTRODUCTION 1 Operator s Manual Marine Diesel Engines Revision 0 05 2016 U_MIE1_EN U_MIF1_EN Rev 0...
Страница 2: ...INTRODUCCION 2 Operator s Manual Marine Diesel Engines Revision 0 05 2016...
Страница 45: ...ELECTRICAL DIAGRAMS 45 Operator s Manual Marine Diesel Engines Revision 0 05 2016 Section 10 Wiring Diagrams...
Страница 48: ...OVERALL DIMENSIONS 48 Operator s Manual Marine Diesel Engines Revision 0 05 2016 Section 11 Overall Dimensions...
Страница 55: ......
Страница 56: ...U_ MIE1_EN U_MIF1_EN Rev 0...