SVT CONTROL PANEL
18
Operator’s Manual Marine Diesel Engines
Revision 0. 05/2016
4.3. Settings
TACHOMETER CALIBRATION
The tachometers supplied with the panel are calibrated in the factory. The user must only
calibrate tachometers purchased as spare parts.
The tachometer can be calibrated with the switch at the rear. To know its position, the
pulley ratio must be calculated.
After calculating the pulley ratio, refer to the table (approximate value, if required) and
rotate the tachometer switch.
If the pulley ratio is not exactly the same as in the table, the
calibration must be completed with the Calibrator (CAL).
Introduce a small flat screwdriver into the calibrator (CAL) at
the rear of the meter. Carefully calibrate the mechanism
moving the meter needle forwards or backwards until it
corresponds to the engine speed.
REPLACING THE LIGHT BULB
Unscrew the cap of the light bulb (rear of the meters) and
change the light bulb
.
Tachometer switch