December 2020
|
Solar Stik
®
, Inc.
44
|
SYSTEM SETUP AND OPERATION GUIDE FOR THE SOLAR STIK USAF G-BOSS MEDIUM AND HEAVY HYBRID POWER SYSTEM
PRELIMINARY DRAFT
Range: 5 A to 60 A
Range: GEL, Flooded, AGM1 AGM2,
Custom
. . . . . . .
SETUP
Status
03 Charger Setup
03A AC Input
Amps = 25A
03C Battery Type
CC/CV
Set Battery Type
GEL
Set Battery Type
AGM1
Set Battery Type
AGM2
Set Battery Type
Custom
Range: 60-100 VAC; Default 70 VAC
03B VAC Dropout
80 VAC
Set Battery Type
CC/CV
Set CV Chg Done
HOLD CV/CHG VDC
Set CV Charge
Volts =
29.0
Set Max Charge
AMPS =
110
Set CV Chg Done
Time = 0.1-25.5Hrs
Set CV Chg Done
HOLD CV/CHG VDC
Options: Time, Hold,
CV, Chg, Amps
Set Max CC/CV
Time = 0.1-25.5 Hrs, off
Set Recharge
Volts = 24-32
Range: 0.0 to 25.5 Hrs
Range: Float, Silent, Multi
03F Max Charge
CC/CV Controlled
03G Final Charge
CC/CV Controlled
Set Max Charge
Time =12.0 Hrs
Set Final Charge
Stage = Silent
Set Final Charge
Stage = Float
Set Final Charge
Stage = Multi
Range: Time, Amps, SOC
Range: 0.1 to 25.5 Hrs
Range: 0 to 250 ADC
Range: 50% to 100%
03D Absorb Done
CC/CV Controlled
Set Absorb Done
Time = 1.0 Hrs
Set Absorb Done
Amps = 20 ADC
Set Absorb Done
SOC = 100%
Set Absorb Done
Time
Set Absorb Done
Amps
Set Absorb Done
SOC
03E Max Charge
Rate = 100%
Set Max Charge
Rate = 0-100%
Set Rebulk Voltage
Volts = 24.0
Range: 24.0 to 32.0 VDC
03H EQ Reminder
CC/CV Controlled
Set EQ Reminder
Days = 1-255 days
Setup: 03 Charger
SETUP Button Menus continued
Continued on next page