PSS-G/RAID Alternative Energy System Deployment Guide
August 2020
|
Solar Stik
®
Inc.
132
|
Enter “Advanced Information Menu”.
Advance to “VIEW CHARGE UNIT
STATUS”.
Press and hold SELECT for 4 seconds.
The number “0” displays in the upper
left corner. This is the MASTER/
CHARGE UNIT #0. This window
reports solar input voltage and
current, output current to batteries,
and the internal temperature for the
pair of solar panels connected to
the ports labeled MASTER/CHARGE
UNIT #0.
Press NEXT.
The number “1” displays in the upper
left corner. This is SLAVE1, CHARGE
UNIT#1. This window reports same
as the master but for the pair of solar
panels connected to SLAVE1 input
ports.
Press NEXT.
The number “2” displays in the upper
left corner. This is SLAVE2, Charge
Unit#2. This window reports same
as the master but for the pair of solar
panels connected to SLAVE2 input
ports.
Press NEXT.
The number “3” displays in the left
corner. The rest of the screen is
blank because no charge controller
occupies this channel.
Note: Menu windows for Charge
Units 3-7 contain only the Unit # in
the upper left hand corner
Press BACK to exit this submenu.
Navigating the User Interface Menus “View Charge Unit Status” Submenus
VIEW CHARGE UNIT
STATUS SEL
0 +27C OUT 12.3A
IN 47.5V 22.0A
1 +27C OUT 14.3A
IN 48.5V 25.0A
2 +27C OUT 12.9A
IN 48.5V 22.2A
Output
current
to batteries
PV Input
current
PV Input
voltage
3-7 (blank/unused)
Charge
Unit #
Internal
Temperature
Power Hub User Interface Menus
Advanced
Information
Menu
LAST FULL CHARGE
10 DAYS AGO
ENTER SETUP
MENUS
SEL
General
Information
Menu
BATTERY VOLT/AMP
26.4V +
15.0A
INPUT
CHG OUT
+10.5A +
15.0A
BATTERY AMP HOURS
FROM FULL
-15
BATTERY CAPACITY
___ 70%
ENTER ADVANCED
DSPLY/SETUP SEL
[Additional Menu
Options]
[Additional Menu
Options]
VIEW CHARGE UNIT
STATUS SEL
Charge Unit Submenus
Figure 71. View Charge Unit Status submenu navigation