![Sola ARGO Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/sola/argo/argo_starting-manual_1312875065.webp)
- 65 -
Fig. 8.20
Fig. 8.20
CALIBRATION
1 . Start
Metering Unit
Operating Speed
Target Rate
Calibration Factor
Speed
min.
max.
g/rotation
Fig. 8.21
Fig. 8.21
IMPORTANT:
CHECK THE CONDITION OF THE
FOAM ON THE DROP DOOR TO ENSURE THAT
THE DISPENSER IS PROPERLY SEALED. IF THE
FOAM IS IN A POOR CONDITION OR THE DROP
DOOR IS NOT MOUNTED IN ITS WORKING
POSITION (FIG 8.21), THE CORRECT PRESSURE
WILL NOT BE DELIVERED TO THE HOPPER AND
SOME PRODUCT WILL BE LOST AT THIS POINT.
7-
With the controller configured, hold down the calibration
button (Fig. 8.22) so that it starts the calibration test.
H
OLD DOWN THE BUTTON TO COLLECT THE
MAXIMUM AMOUNT OF PRODUCT, THE LARGER
THE AMOUNT OF PRODUCT COLLECTED, THE
MORE ACCURATE THE CALIBRATION TEST WILL BE.
Fig. 8.22
Fig. 8.22
PERFORM THE CALIBRATION TEST ON ALL OF THE
MACHINE'S DISPENSERS. (Fig. 8.23).
Fig. 8.23
Fig. 8.23
CALIBRATION
1 . Start
Metering Unit
Operating Speed
Target Rate
Calibration Factor
Speed
min.
max.
g/rotation
IMPORTANT:
FOR DOSES WHERE THE TOTAL
AMOUNT OF PRODUCT IS AROUND 400 Kg/Ha
(BEAR IN MIND SEEDS AND/OR FERTILISER),
CHECK TO ENSURE THAT THERE IS NO
BUILD-UP OF MATERIAL OR CLOGGING OF THE
PNEUMATIC SYSTEM. IF THERE IS, YOU MUST
REDUCE THE DOSE OR WORKING SPEED.
IMPORTANT:
AFTER COVERING THE FIRST
HECTARE, VERIFY THAT THE DESIRED AMOUNT
OF PRODUCT IS BEING USED.