FUNCTION Button/Logging Data
14
P/N: 1006148-01
Display P
a
nel Oper
ations
FUNCTION Button/Logging Data
This button switches the receiver between
information modes and post-processing
modes, starts/stops data recording, and
changes the baud rate of the serial port to
9600. The FUNCTION button enables you
to turn data recording on or off. See Table 7
to learn how to use the FUNCTION button.
Each time data recording is turned off or
on, either a new file opens or data appends
to a particular file.
Figure 9: FUNCTION Button
FUNCTION
FUNCTION
Press the FUNCTION
button for 1–5
seconds to start/stop
data logging.
FUNCTION
Button
Table 7. FUNCTION Button Operations and REC LED Status
FUNCTION Key
REC LED
Status
When data recording is off, and the FUNCTION key is...
Not pressed
No light
No data recording.
Orange blink
Internal file system test in progress.
Red
No free memory; hardware problem with data
recording. No SDHC card.
Pressed for < 1
second
If FUNCTION key mode is “LED blink mode switch”
Orange
Release to change information mode.
If FUNCTION key mode is “Occupation mode switch”
Orange
No function.
Pressed for 1–5
seconds
If FUNCTION key mode is “LED blink mode switch”
Green
Release to start data recording (post-processing
occupation mode undefined).
If FUNCTION key mode is “Occupation mode switch”
Green
Release to start recording (Kinematic or Static post-
processing occupation mode).
Pressed for 5–8
seconds
Red
Release to turn serial port A baud rate to 9600 bps.
Pressed for > 8
seconds
No light
No function.