AC Output Data (ON-Grid )
Datasheet
HYD
3000-EP
HYD
3680-EP
HYD
4000-EP
HYD
4600-EP
HYD
5000-EP
HYD
5500-EP
HYD
6000-EP
Nominal AC
power
(
W
)
3000
3680
4000
4600
5000
5000
6000
Max. AC power
output to utility
grid
(
VA
)
3300
3680
4400
4600
5000
5500
6000
Max. AC power
from utility grid
(VA)
6000
7360
8000
9200
10000
10000
12000
Max. AC
current output
to utility grid
15A
16A
20A
20.9A
21.7A
25A
27.3A
Max. AC
current from
utility grid
27.3A
32A
36.4A
41.8A
43.4A
43.4A
54.6A
Output Current
(inrush)
55A,2uS
55A,2uS
55A,2uS
55A,2uS
55A,2uS
55A,2uS
55A,2uS
Rated apparent
power
(
VA
)
3600VA
4400VA
4800VA
5520VA
6000VA
6000VA
6000VA
Maximum
output fault
current
32.5A,10
uS
34.5A,10
uS
35.25A,
10uS
43A,
10uS
43A,
10uS
44A,
10uS
48A,
10uS
Maximum
output
overcurrent
protection
30.5A,
10uS
32.5A,
10uS
33.25A,
10uS
41A,
10uS
41A,
10uS
42A,
10uS
46A,
10uS
Nominal grid
voltage
L/N/PE, 220Vac, 230Vac,240Vac
Grid voltage
range
180Vac~276Vac(According to local standard)
Nominal
frequency
50/60Hz
Grid Frequency
range
45Hz~55Hz/55Hz~65Hz
Power factor
1 default (adj/-0.8)
Output THDi
(@Nominal
output)
<3%