SOFAR 15~24KTLX-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 29 -
Figure 5-5 Incorrect connection between load and inverter
The resistance at connection point must less than 2
Ω
. In case to have a properly
anti-islanding function, please choose the high-quality PV cable and ensure the
power loss is less than 1%. Meanwhile, the inverter AC side to grid connection
point must less than 100m. the relation between cable length, cross section area
and power loss as below:
Figure 5-6 relation between cable length, cross section area and power loss
The AC output terminal of this product is equipped with high current 5-core
terminal block and customized AC output waterproof cover, which can meet the
IP65 level requirements after installation. AC cable need customer self connect, the
out looking is as below figure 5-7: