![Sofar solar 15KTLX-G3 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/sofar-solar/15ktlx-g3/15ktlx-g3_user-manual_1311968055.webp)
SOFAR 15~24KTLX-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 51 -
(A)Enter setting Interface as below
:
1.Enter Setting
--------Long press DOWN button
1.Set time
9.Set Language
2.Clear Energy
10.Set AntiReflux
3.Clear Events
11.Logic Interface
4.Set Country
12.IV Curve Scan
5.On-Off Control
13.PCC Select
6.Set Energy
14.Reflux Mode
7.Set Address
15.Autotest Fast
8.Set Input mode
16.Autotest STD
Long press the button to Enter the main interface of "1. Enter Setting" and
long press to enter the setting menu. You can select the content you want to set by
short pressing the button.
Note1: Some settings need to enter the password (the default password is
0001), when entering the password, short press to change the number, long press
to confirm the current number, and long press after entering the correct password.
If "password error, try again" appears, you will need to re-enter the correct
password.
1. Set Time
Set the system time for the inverter.
2. Clear Energy
Clean the inverter of the total power generation.
3. Clear Events
Clean up the historical events recorded in the inverter.
4. Set Country
This menu is where you can select the country grid parameters, alternatively
you can use the mobile APP. To import a country profile you will require the use of
a USB drive. Once you insert a USB drive with a valid file you can then select and
import it in the "Set SafetyPara" menu.
To use the Bluetooth APP to select the correct country code, the account must
be linked and authorised as an installer. Once the country is set, it is read-only and