SOFAR 15~24KTLX-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 65 -
rectified. If no, please contact
technical support.
AC)
sampling
(
AC
side
)
ID23
HwADFaultIdcBr
anch
Current Branch
sampling faulty
ID24
HwADFaultIdc
DC input current
sampling faulty
ID29
ConsistentFault_
GFCI
The GFCI
sampling value
between the
master DSP and
salve DSP is not
consistent
ID30
ConsistentFault_
Vgrid
The Grid voltage
sampling value
between the
master and
salve is not
consistent
ID31
ConsistentFault_
DCI
3 lines' DCI
consistency error
There are internal faults of inverter,
turn OFF the
“
DC switch
”
, wait for
5 minutes, then turn ON the
“
DC
switch
”
. Check whether the fault is
rectified. If no, please contact
technical support.
ID33
SpiCommFault(D
C)
SPI
Communication
Faulty
(
DC side
)
ID34
SpiCommFault(A
C)
SPI
Communication
Faulty
(
AC side
)
ID35
SChip_Fault
Chip Faulty
(
DC
side
)
ID36
MChip_Fault
Chip Faulty
(
AC
side
))
ID37
HwAuxPowerFau
lt
Auxiliary power
fault
ID41
RelayFail
Relay faulty
Please check whether the
resistance to ground of PV string is
too low and whether the insulation
of PV cable is damaged. If the use
ID42
IsoFault
Low isolation
faulty
ID43
PEConnectFault
Ground faulty