SOFAR 15~24KTLX-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 69 -
P
hardware
overcurrent
ID100
Reserved
Reserved
There are internal faults of inverter,
turn OFF the
“
DC switch
”
, wait for
5 minutes, then turn ON the
“
DC
switch
”
. Check whether the fault is
rectified. If no, please contact
technical support.
ID102
HwPVOCP
PV hardware
overcurrent
ID103
HwACOCP
AC output
hardware
overcurrent
ID110
Overload1
Overload
Protection 1
ID111
Overload2
Overload
Protection 2
ID112
Overload3
Overload
Protection 3
ID113
OverTempDerati
ng
Overtemperature
derating
Ensure the installation position and
installation method meet the
requirements of this user manual.
Check whether the ambient
temperature of the installation
position exceeds the upper limit. If
yes, improve ventilation to
decrease the temperature.
Check whether the inverter has
dust and dust, whether there are
foreign matters blocking the fan at
the air inlet. If so, please improve
the ventilation and heat dissipation
of the environment. It is
recommended that the inverter
should be cleaned once every half a
year.