SETUP PROCEDURES
Calibrate the Empty Hopper Setting
(
Cb
and
EH
Codes)
Calibrating the empty hopper setting enables the cab
control to alert the operator when the hopper is empty.
Recalibrate the empty hopper setting at the start of
each ice-control season.
1. Ensure that the hopper is empty before beginning
the calibration.
2. Turn the vehicle ignition to ACC or ON. Press
the ON/OFF button on the cab control to turn the
control ON.
3. Press and hold the control knob for approximately
10 seconds until the
Cb
code displays.
4. The calibration cycle will begin. The blue LEDs
around the knob will illuminate in succession until
all eight are lit.
5. When the automatic calibration cycle is complete,
the control will automatically revert to the previous
material application settings.
If the control is turned OFF or loses power during
the calibration cycle, the calibration data will be lost.
Make sure the control is ON and restart the calibration
process at Step 3.
Once the empty hopper setting has been calibrated,
the
EH
code will flash on the display and a beep will
sound whenever the hopper is empty. The
EH
code is
informational only and will not stop spreader operation.
Clearing Empty Hopper Calibration Data (
Cc
Code)
The empty hopper calibration may be cleared, if
desired. The control will no longer display the
EH
status code when the hopper is empty.
Start the calibration cycle as described above. At
Step 4, press the control knob during the calibration
cycle to clear
all
calibration data. The
Cc
(Clear
Calibration) code will display and the control will exit
Cc
mode automatically.
Adjust LED Brightness Level
(
SL
and
LS
Codes)
The brightness setting of the cab control lights can be
adjusted from 1 to 16. The factory default setting is 8.
1. Turn the vehicle ignition to ACC or ON. If
necessary, press the cab control ON/OFF button
to turn the control OFF.
2. Press and hold the control knob for approximately
3 seconds until the
LS
code is displayed.
3. Release the knob and turn it clockwise or
counterclockwise to increase/decrease the
brightness level. The light level number will show
in the status display.
4. After selecting the desired brightness level, wait
a few seconds for the
SL
confirmation code to
display.
NOTE: A brightness level setting of 12 or higher is
recommended for daylight conditions.