LC2000/LC2000-IQ/LC4000/LC4000-IQ
System Setup Menus
Issue 1 Rev 6
Page 50
© 2015 SAM
7.10 Logging
Logging defines what parameter information is made available to a logging device attached to
the RollCall network.
You can select from any of the following logging options:
•
Serial Number
•
Uptime (how long the unit has been powered up, in days/hours/minutes/seconds)
•
PSU 1 State, PSU 2 State
•
Reference Standard
7.11 Status
The Status menu shows the status of the unit’s hardware and software.
•
Software Version:
The currently installed software version.
•
Serial Number:
The unique serial number of the unit.
•
PSU A, PSU B:
The PSU voltage.
•
Module 1 Temperature:
The current temperature of the FPGA module.
•
Dolby Ch 1 and Ch 2:
Whether the Dolby channel is available.
7.12 Calibration (LC2000/LC4000 Only)
The Calibration menu enables you to calibrate the CVBS decoders and encoders.
7.12.1 CVBS Decoder/Encoder A–D
•
Luma Gain:
Adjusts the composite luminance signal.
•
Chroma Gain:
Adjusts the composite chrominance signal.
•
Y/C Chroma Gain:
Adjusts the component Y/C chrominance signal.
•
Save Decoder:
Saves the gain settings.
7.12.2 CVBS Encoder A–D
•
DAC Gain:
Adjusts the DAC video output gain level.
•
Save:
Saves the gain setting.
Note:
CVBS calibration is not required in normal operation. If calibration is required, it should only