To adjust profile:
1. Select
Profile
from the toolbar.
The Profile window opens below the main body of the screen.
2. Use the touch screen or the control keys to make changes to the Profile:
–
Profile
—switches the trace on and off.
–
Probe
—identifies the type of test probe being used.
–
Peak
—maximizes the signal sampling rate for capturing fast events, such as voltage
spikes, dropouts, and glitches.
–
Filter
—removes noise and interference from the trace.
–
Invert
—switches the polarity of the displayed signal.
–
Coupling AC
—blocks the DC portion of an input signal in order to amplify the AC portion.
–
Scale
—adjusts the total value displayed on the vertical axis of the display.
–
Trigger
—switches triggering on or off, and determines which slope of the trace trigger.
3. Tap
Profile
on the toolbar or press
N/X
to move focus back to the toolbar once you are
finished making adjustments.
For more detained information about adjusting how a sampled signal displays on the screen refer